Product videos

Fluke 319

General Specifications
Digital Display
 6000 count resolution
Low Battery Indication
 Displays a signal when the batteries are below their required voltage
Power Source
 Three AAA IEC LR03 batteries
Clamp Opening Size
 1.45 in (37 mm)
Jaw Diameter
 1.45 in (37 mm)
Dimensions (L x W x H)
 6.39 in x 2.29 in x 1.20 in
 (162.4 mm x 58.25 mm x 30.5 mm)
Weight
 approximately 13.5 oz (384 g) (batteries included)
Auto Range
 Available in Ohms
Safety
 CE
 EN/IEC 61010-1 and IEC 61010-2-032
 Measurement Category: 600V CAT III

317 Electrical Specifications
Current AC
Range 40.00 A, 600.0 A
Resolution 0.01 A, 0.1 A
Accuracy 1.6% ± 6 digit (50-60 Hz) {40 A}
 2.5% ± 8 digit (60-500 Hz) {40 A}
 1.5% ± 5 digit (50-60 Hz) {600 A}
 2.5% ± 5 digit (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response rms
Current DC
Range 40.00 A, 600.0 A
Resolution 0.01 A, 0.1 A
Accuracy 1.6% ± 6 digit (40 A)
 1.5% ± 5 digit (600 A)
Voltage AC
Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ± 5 digit (20-500Hz)
AC response rms
Voltage DC
Range 600.0 V
Resolution 0.1 V
Accuracy 1% ± 4 digit
Resistance
Range 400.0 Ω, 4000 Ω
Resolution 0.1 Ω, 1 Ω
Accuracy 1% ± 5 digit
Continuity
 ≤ 30 Ω
Inrush
Integration time N/A
Frequency
Range N/A
Accuracy N/A
Trigger Level N/A

319 Electrical Specifications
Current AC
Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ± 6 digit (50-60 Hz) {40 A}
 2.5% ± 8 digit (60-500 Hz) {40 A}
 1.5% ± 5 digit (50-60 Hz) {600/1000 A}
 2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response rms
Current DC
Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ± 6 digit (40 A)
 1.5% ± 5 digit (600/1000 A)
Voltage AC
Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ± 5 digit (20-500Hz)
AC response rms
Voltage DC
Range 600.0 V
Resolution 0.1 V
Accuracy 1% ± 4 digit
Resistance
Range 400.0 Ω
 4000 Ω
Resolution 0.1 Ω
 1 Ω
Accuracy 1% ± 5 digit
Continuity
 ≤ 30 Ω
Inrush
Integration time 100 ms
Frequency
Range 5.0 - 500.0 Hz
Accuracy 0.5% ± 5 digit
Trigger Level 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A

The accuracy specifications aply at 73 °F ± 41 °F (23 °C ± 5 °C)

Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. 

True rms for ac V and ac A accuracy is specified from 5% to 100% of range.

Environmental Specifications
Operating Temperature
 14°F to 122°F (-10 °C to 50 °C)
Storage Temperature
 -40 °F to 140 °F (-40 °C to 60 °C)
Operating Humidity
 Non condensing (< 50 °F) (< 10 °C)
 90 % RH (50 °F to 86 °F) (10 °C to 30 °C)
 75 % RH (86 °F to 104 °F) (30 °C to 40 °C)
 45 % RH (104 °F to 122 °F) (40 °C to 50 °C)
 (Without Condensation)
Operating Altitude
 1 mile (2000 meters) above mean sea level
Storage Altitude
 7 miles (12,000 meters) above mean sea level
IP Rating
 IP40
Vibration Requirements
 Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop Test Requirements
 3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC
 Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature Coefficients
 0.1x (specified accuracy)/ °C
 (<64 °F or > 82° F)
 (<18 °C or > 28 °C)

Fluke 319

Free Shipping

This product qualifies for free air shipping.

  • Views: 1590
  • Product: Clamp Meter AC/DC 1000A
  • Availability: In Stock
  • Rs 38,000

Tags: fluke 319 fluke, clamp, meters