Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 17B+ digital multimeter does all that and more. Common basic electrical measurements plus temperature, frequency and duty cycle. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need.
Features:
600 V Cat III safety rating
50% bigger display with bright white backlight
Over-voltage indicator
Frequency and temperature measurement
Voltage, resistance, continuity, capacitance
Input terminal for ac and dc current measurements to 10 A current
Diode test, data hold
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.
Function
Overload Protection
Input Impedance (Nominal)
Common Mode Rejection Ratio
Normal Mode Rejection Ratio
AC volts
1000 V 1
>10 MΩ <100 pF
>60 dB at dc, 50 Hz or 60 Hz
-
AC millivolts
400 mV
>1MΩ, <100 pF
>80 dB at 50 Hz or 60 Hz
-
DC volts
1000 V 1
>10 MΩ <100 pF
>100 dB at dc, 50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts
400 mV
>1MΩ, <100 pF
>80 dB at 50 Hz or 60 Hz
-
1 106 V Hz Max
General Specifications
Maximum voltage between any terminal and earth ground
1000 V
Display (LCD)
4000 counts, updates 3/sec
Battery type
2 AA, NEDA 15A, IEC LR6
Battery life
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating
0 °C to 40 °C
Storage
-30 °C to 60 °C
Relative Humidity
Operating humidity
Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C; ≤75% RH at 30 °C to 40 °C
40 MΩ range ≤80% RH at 10 °C to 30 °C; ≤70% RH at 30 °C to 40 °C
Altitude
Operating
2000 m
Storage
12,000 m
Temperature coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs
440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only.
Size (HxWxL)
183 x 91 x 49.5 mm
Weight
455 g
IP rating
IP 40
Safety
IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment
IEC 61326-1: Portable
Electromagnetic compatibility
Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1 1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.