Product videos
Fluke 116
Overview:
- With
the ability to take temperature and microamp measurements, the Fluke 116
Digital Multimeter has everything you need to help you quickly
troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116
measures resistance, continuity, frequency and capacitance. Fluke 116
multimeters are independently tested for safe use in CAT III 600 V
Environments.
Features:
- Built-in
thermometer for HVAC applications
- Microamps
to test flame sensors
- Low
input impedance: helps prevent false readings due to ghost voltage
- Large
white LED backlight to work in poorly lit areas
- Resistance,
continuity, frequency and capacitance
- Min/Max/Average
with elapsed time to record signal fluctuations
- Compact
ergonomic design for one-handed operation
- Compatible
with optional magnetic hanger (ToolPak™)
- CAT
III 600 V safety rated
Specifications |
||
Maximum voltage between any terminal and earth ground |
600 V |
|
Surge protection |
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 |
|
Display |
Digital: 6,000 counts, updates 4 per second |
|
Bar graph |
33 segments, updates 32 per second |
|
Operating temperature |
-10°C to + 50°C |
|
Storage temperature |
-40°C to + 60°C |
|
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
Battery life |
400 hours typical, without backlight |
|
Accuracy Specifications |
||
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
DC volts |
Range/resolution |
6.000 V / 0.001 V |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
Auto volts |
Range/resolution |
600.0 V / 0.1 V |
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) |
|
AC millivolts1 True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
AC volts1 True RMS |
Range/resolution |
6.000 V / 0.001 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or
shorts of |
|
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω |
Accuracy |
0.9% + 1 |
|
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
|
Accuracy |
5% + 2 |
|
Diode Test |
Range/resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
|
Capacitance |
Range/resolution |
1000 nF / 1 nF |
Accuracy |
1.9% + 2 |
|
Range/resolution |
> 1000 μF |
|
Accuracy |
5% + 20% |
|
Lo-Z Capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
|
Temperature² |
Range/resolution |
-40°C to 400°C / 0.1°C |
Accuracy |
1% + 10² |
|
Range/resolution |
-40°F to 752°F / 0.2°F |
|
Accuracy |
1% + 18² |
|
AC μA true-rms (45 Hz to 500 Hz) |
Range/resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.5% + 3 |
|
DC μamps |
Range/resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
|
Hz (V or A input)² |
Range/resolution |
99.99 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |