"All prices are subject to change without prior notice due to currency fluctuation Please confirm prices before placing the order to avoid any confusion"
SOLD OUT Fluke 116 Digital HVAC Multimeter

Product videos

Fluke 116

Overview:


  • With the ability to take temperature and microamp measurements, the Fluke 116 Digital Multimeter has everything you need to help you quickly troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116 measures resistance, continuity, frequency and capacitance. Fluke 116 multimeters are independently tested for safe use in CAT III 600 V Environments.
Features:


  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated


Specifications

Maximum voltage between any terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to + 50°C

Storage temperature

-40°C to + 60°C

Battery type

9 volt Alkaline, NEDA 1604A/ IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V

Accuracy

±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution

600.0 V / 0.1 V

Accuracy

2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)

AC millivolts1 True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts1 True RMS

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/Resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode Test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z Capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

Temperature²
(Type-K thermocouple)

Range/resolution

-40°C to 400°C / 0.1°C

Accuracy

1% + 10²

Range/resolution

-40°F to 752°F / 0.2°F

Accuracy

1% + 18²

AC μA true-rms (45 Hz to 500 Hz)

Range/resolution

600.0 μA / 0.1 μA

Accuracy

1.5% + 3

DC μamps

Range/resolution

600.0 μA / 0.1 μA

Accuracy

1.0% + 2

Hz (V or A input)²

Range/resolution

99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz

Accuracy

0.1% + 2

Fluke 116

  • Views: 2725
  • Product: Digital HVAC Multimeter
  • Availability: SOLD OUT
  • Rs 33,500
  • Free Shipping
whatsapp