-4% Fluke 376FC True-rms AC/DC Clamp Meter with iFlex 1000A

Product videos

Fluke 376FC

  • The Fluke 376 FC is part of the Fluke Connect family of wireless test tools.  Now you can:

    • Log and trend measurements to pinpoint intermittent faults
    • Transmit results wirelessly via Fluke Connect® Measurements app
    • Create and send reports right from the field
    • Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices
    The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.
    • Connect your meter to your smartphone with Fluke Connect Measurements
    • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
    • Record results directly to your phone and the Cloud
    • Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
    • Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
    • iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
    • TPAK magnetic hanging strap (included)
    • Integrated VFD low pass filter for accurate motor drive measurements
    • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
    • CAT IV 600 V, CAT III 1000 V safety rating
    • Three-year warranty
    • Soft carrying case
    Measurement Capability
    • 1000 A ac and dc current measurement
    • 2500 A ac current measurement with iFlex flexible current probe
    • 1000 V ac and dc voltage measurement
    • True-rms voltage and current for accurate measurements on non-linear signals
    • Frequency measurement to 500 Hz with body jaw and iFlex
    • Resistance measurement to 60 kΩ with continuity detection
    • Min, max, average, and inrush recording to capture variations automatically
    • 500 mV dc measurement range to interface with other accessories
    • 1000 μF capacitance measurement
    • General Specifications
      AC Current via Jaw
      Range999.9 A
      Resolution 0.1 A
      Accuracy 2% ±5 digits (10 Hz to 100 Hz)
      2.5% ±5 digits (100-500 Hz)
      Crest Factor (50 Hz/60 Hz)3 @ 500 A
      2.5 @ 600 A
      Add 2% for C.F. >2
      AC Current via Flexible Current Probe
      Range2500 A
      Resolution0.1 A (≤ 600 A)
      1 A (≤ 2500 A)
      Accuracy3% ±5 digits (5 – 500 Hz)
      Crest Factor (50/60Hz)3.0 at 1100 A
      2.5 at 1400 A
      1.42 at 2500 A
      Add 2% for C.F. > 2
      Position Sensitivity
      Flexible current probe
       i2500-10 Flexi2500-18 Flex
      A  
      Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)
      Error±0.5 %±0.5 %
      B  
      Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)
      Error±1.0 %±1.0 %
      C  
      Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)
      Error±2.0 %±2.0 %
      Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
      DC Current
      Range600.0 A
      Resolution0.1 A
      Accuracy2% ±5 digits
      AC Voltage
      Range1000 V
      Resolution0.1 V (≤600.0 V)
      1 V (≤1000 V)
      Accuracy1.5% ±5 digits (20 Hz to 500 Hz)
      DC Voltage
      Range1000 V
      Resolution0.1 V (≤600.0 V)
      1 V (≤1000 V)
      Accuracy1% ±5 digits
      mV dc
      Range500.0 mV
      Resolution0.1 mV
      Accuracy1% ±5 digits
      Frequency via Jaw
      Range5.0 Hz to 500.0 Hz
      Resolution 0.1 Hz
      Accuracy 0.5% ±5 digits
      Trigger level 5 Hz to 10 Hz, ≥10 A
      10 Hz to 100 Hz, ≥5 A
      100 Hz to 500 Hz, ≥10 A
      Frequency via Flexible Current Probe
      Range5.0 Hz to 500.0 Hz
      Resolution 0.1 Hz
      Accuracy 0.5% ±5 digits
      Trigger level 5 Hz to 20 Hz, ≥25 A
      20 Hz to 100 Hz, ≥20 A
      100 Hz to 500 Hz, ≥25 A
      Resistance
      Range60 kΩ
      Resolution0.1 Ω (≤600 Ω)
      1 Ω (≤6000 Ω)
      10 Ω (≤60 kΩ)
      Accuracy1% ±5 digits
      Capacitance
      Range1000 μF
      Resolution0.1 μF (≤ 100 μF)
      1 μ F (≤ 1000 μF)
      Accuracy1% ±4 digits
      Mechanical Specifications
      Maximum voltage between any terminal and earth ground1000 V
      Batteries2 AA, NEDA 15A, IEC LR6
      Operating temperature-10 °C to +50 °C
      Storage temperature-40 °C to +60 °C
      Operating humidity -
      non-condensing (< 10°C)
      ≤90% RH (at 10 °C to 30 °C)
      ≤75% RH (at 30 °C to 40 °C)
      ≤45% RH (at 40 °C to 50 °C)


Fluke 376FC

  • Views: 5972
  • Product: True-rms AC/DC Clamp Meter with iFlex 1000A
  • Availability: In Stock
  • Rs 120,000
  • Rs 115,000
  • + Rs 500 Shipping charges:
whatsapp