"All prices are subject to change without prior notice due to currency fluctuation Please confirm prices before placing the order to avoid any confusion"
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex 999.9 A

Product videos

Fluke 381

Overview:

Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.
The iFlex  Flexible Current Probe (included) expands the measurement range to 2500A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires.

Features and Benefits:
  • Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement for added flexibility without interference with measurement accuracy
  • The removable magnetic display can be conveniently mounted where it is easily seen
  • iFlex Flexible Current Probe expands the measurement range to 2500 A AC
  • CAT IV 600 V, CAT III 1000 V
  • Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
 

Electrical Specifications:

AC Current via Jaw

Range

999.9 A

Resolution

0.1 A

Accuracy

2% ± 5 digits (10-100 Hz)
5% ± 5 digits (100-500 Hz)

Crest Factor (50/60 Hz)

3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2% for C.F. > 2

AC Current via Flexible Current Probe

Range

999.9 A / 2500 A (45 Hz – 500 Hz)

Resolution

0.1 A / 1 A

Accuracy

3% ± 5 digits

Crest Factor (50/60 Hz)

3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2

Position Sensitivity

Flexible current probe

Distance from Optimum

 

i2500-10 Flex

i2500-18 Flex

Error

A

0.5 in (12.7 mm)

1.4 in (35.6 mm)

±0.5%

B

0.8 in (20.3 mm)

2.0 in (50.8 mm)

±1.0%

C

1.4 in (35.6 mm)

2.5 in (63.5 mm)

±2.0%

 

Fluke 381

  • Views: 4365
  • Product: Remote Display True RMS AC/DC Clamp Meter with iFlex 999.9 A
  • Availability: In Stock
  • Rs 113,000
  • Free Shipping
whatsapp

Tags: fluke, 381, clamp, meters, remote display true, rms, ac/dc, with, iflex, 999.9