"All prices are subject to change without prior notice due to currency fluctuation
Please confirm prices before placing the order to avoid any confusion"
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes. (The Multiple Earthing System.) • True RMS Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A • Noise Check Function A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD. • Memory function Save and display up to 100 measurement data. • Data hold function / Buzzer function / Back light function • Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2
Note: A single earthing can not be measured. (Only for Multiple Earthing System)
Earth Resistance Auto Range
Ranges
20Ω 200Ω 1200Ω
Resolution
20Ω: 0.01Ω 200Ω: 0.1Ω 1200Ω: 1Ω, 10Ω
Measuring Range
0.00 to 20.99Ω 16.0 to 99.9Ω, 100.0 to 209.9Ω 160 to 399Ω, 400 to 599Ω 600 to 1260Ω
Accuracy
20Ω: ±1.5% ±0.05Ω 200Ω: ±2%±0.5Ω at 16.0 to 99.9Ω 200Ω: ±3% ±2Ω at 100.0 to 209.9Ω 1200Ω: ±5% ±5Ω at 160 to 399Ω 1200Ω: ±10% ±10Ω at 400 to 599Ω
AC Current Auto Range (50Hz/60Hz)
Ranges
100mA 1000mA 10A 30A
Resolution
0.1mA 1mA 0.01A 0.1A
Measuring Range
0.0 to 104.9mA 80 to 1049mA 0.80 to 10.49A 8.0 to 31.5A