FLUKE 124B

Fluke 124B Specifications

Oscilloscope Mode (Vertical)
Frequency Response - DC CoupledWithout probes and test leads (with BB120): DC to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)
With VP41 10:1 probe: DC to 40 MHz (-3 dB)
Frequency Response - AC Coupled (LF Roll Off)Without probes and test leads: <10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB)
With VP41 10:1 probe: <10 Hz (-3 dB)
Rise Time, Excluding Probes, Test Leads<8.75 ns
Input ImpedanceWithout probes and test leads: 1 MΩ/20 pF
With BB120: 1 MΩ/24 pF
With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF
With VP41 10:1 probe: 5 MΩ/15.5 pF
Sensitivity5 mV to 200 V/div
Analog Bandwidth Limiter10 kHz
Display ModesA, -A, B, -B
Maximum Input Voltage A and BDirect, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage
With BB120: 600 Vrms
Maximum Floating Voltage, from any Terminal to Ground600 Vrms CAT IV, 750 Vrms up to 400 Hz
Oscilloscope Mode (Horizontal)
Scope ModesNormal, single, roll
Ranges (Normal)Equivalent sampling: 10 ns to 500 ns/div
Real time sampling: 1 μs to 5 s/div
Single (real time): 1 μs to 5 s/div
Roll (real time): 1 s to 60 s/div
Sampling Rate (for Both Channels Simultaneously)Equivalent sampling (repetitive signals): up to 4 GS/s
Real time sampling 1 μs to 60 s/div: 40 MS/s
Trigger
Screen UpdateFree run, on trigger
SourceA, B
Sensitivity A and BAt DC to 5 MHz: 0.5 divisions or 5 mV
At 40 MHz: 1.5 divisions
At 60 MHz: 4 divisions
SlopePositive, negative
Advanced Scope Functions
Display ModesNormal: Captures up to 25 ns glitches and displays analog-like persistence waveform
Smooth: Suppresses noise from a waveform
Glitch off: Does not capture glitches between samples
Envelope: Records and displays the minimum and maximum of waveforms over time
Auto Set (Connect-and-View)Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level
Input A and B
DC Voltage (V DC)Ranges: 500 mV, 5, 50, 500, 750 V
Accuracy: ±(0.5% +5 counts)
Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50, 60, or 400 Hz
Full scale reading: 5000 counts
True RMS Voltages (V AC and V AC+DC)Ranges: 500 mV, 5, 50, 500, 750 V
Accuracy for 5 to 100% of range (DC coupled)
DC to 60 Hz (V AC + DC): ±(1% +10 counts)
1 to 60 Hz (V AC): ±(1% +10 counts)

Accuracy for 5 to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts)
DC rejection (only V AC): >50 dB
Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50, 60, or 400 Hz
Full scale reading: 5000 counts, reading is independent of any signal crest factor
PeakModes: Maximum peak, minimum peak, peak-to-peak
Ranges: 500 mV, 5, 50, 500, 2200 V
Accuracy: Maximum peak or minimum peak: 5% of full scale; peak-to-peak: 10% of full scale
Full scale reading: 500 counts
FrequencyRanges: 1, 10, 100 Hz, 1, 10, 100 kHz, 1, 10, and 70 MHz
Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts)
Full scale reading: 10,000 counts
RPMMaximum reading: 50 kRPM
Accuracy: ±(0.5% +2 counts)
Duty CycleRange: 2 to 98%
Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse WidthFrequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading: 1000 counts
AmperesWith current clamp
Ranges: same as V DC, V AC, V AC+DC, or peak
Scale factors: 0.1, 1, 10, 100, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy: same as V DC, V AC, V AC+DC, or peak (add current clamp uncertainty)
Decibel0 dBV: 1 V
0 dBm (600/50 Ω): 1 mW referenced to 600 or 50 Ω
dB on V DC, V AC, or V AC+DC
Full scale reading; 1000 counts
Crest FactorRange: 1 to 10
Full scale reading: 90 counts
PhaseModes: A to B, B to A
Range: 0 to 359°
Resolution: 1°
VpwmPurpose: To measure on pulse width modulated signals, like motor drive inverter outputs
Principle: Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy: As Vrms for sine wave signals
Input A to Common
OhmRanges: 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩ
Accuracy: ±(0.6% +5 counts) 50 Ω ±(2% +20 counts)
Full scale reading: 50 Ω to 5 MΩ - 5000 counts; 30 MΩ - 3000 counts
Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage: <4 V
Common Continuity (Cont)Beep: <(30 Ω ±5 Ω) in 50 Ω range
Measurement current: 0.5 mA
Detection of shorts of: ≥1 ms
Common DiodeMeasurement voltage: At 0.5 mA: >2.8 V
At open circuit: <4 V
Measurement current: 0.5 mA
Polarity: + on input A, - on COM
Capacitance (CAP)Ranges: 50, 500 nF, 5, 50, 500 μF
Full scale reading: 5000 counts
Measurement current: 500 nA to 0.5 mA, increases with increasing ranges
Advanced Meter Functions
Zero SetSet actual value to reference
AutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals
Fixed Decimal PointActivated by using attenuation keys
Cursor Readout
SourcesA, B
Single Vertical LineAverage, minimum and maximum readout
Average, minimum, maximum and time from start of readout (in ROLL mode; instrument in HOLD)
Minimum, maximum and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode
Dual Vertical LinesPeak-peak, time distance and reciprocal time distance readout
Average, minimum, maximum and time distance readout (in ROLL mode; instrument in HOLD)
Dual Horizontal LinesHigh, low and peak-peak readout
Rise or Fall TimeTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode)
AccuracyAs oscilloscope accuracy
Recorder
Meter ReadingsMeasurement speed: Maximum 2 measurements
Record size (minimum, maximum, average): 2 M readings for 1 channel
Recorded time span: 2 weeks
Maximum number of events: 1024
Waveform RecordMaximum sample rate: 400 K samples
Size internal memory: 400 M samples recorded time
Span internal memory: 15 minutes at 500 μs/div - 11 hours at 20 ms/div
Record size SD card: 1.5 G samples
Recorded time span SD card: 11 hours at 500 μs/div - 14 days at 20 ms/div
Maximum number of events: 64
General Specifications
Waveform DisplayVertical: 10 div of 40 pixels
Horizontal: 12 div of 40 pixels
Maximum Input Voltage A and BDirect on input or with leads: 600 Vrms CAT IV for derating
With banana-to BNC adapter BB120: 600 Vrms for derating
Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz
DisplayType: 5.7" color active martrix TFT
Resolution: 640 x 480
InterfaceOptically isolated: Transfer screen copies (bitmaps), settings and data
USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®
Wireless Radio with AdapterFrequency range: 2412 to 2462 MHz
Output power: <100 mW
EnvironmentalMIL-PRF-28800F, Class 2
TemperatureBattery operation: 32 to 104°F (0 to 40°C)
Power adapter operation: 32 to 122°F (0 to 50°C)
Storage: -4 to 140°F (-20 to 60°C) non-condensing
Humidity (Operating)At 32 to 50°F (0 to 10°C): non-condensing
At 50 to 86°F (10 to 30°C): 95%
At 86 to 104°F (30 to 40°C): 75%
At 104 to 122°F (40 to 50°C): 45%
AltitudeOperating at 10,000' (3 km): CAT III 600 V
Operating at 6600' (2 km): CAT IV 600 V
Storage: 40,000' (12 km)
EMC Electromagnetic CompatibilityUSA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103)
Enclosure ProtectionIP51, ref: EN/IEC60529
SafetyGeneral: IEC 61010-1: Pollution Degree 2
Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
MemoryInternal memory can store 20 data sets (screen waveform and setup)
Micro SD card slot with optional SD card (maximum size of 32 GB)
PowerExternal: Via power adapter BC430
Input voltage: 10 to 21 V DC Consumption: 5 W typical
Input connector: 5 mm jack
Internal: Via battery pack BP290
Battery power: Rechargeable Li-Ion 10.8 V
Operating time: 7 hours with 50 % backlight brightness
Charging time: 4 hours with test tool off, 7 hours with test tool on
Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging
Dimensions10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)
Weight3.2 lbs (1.4 kg) including battery pack