Product videos
Fluke 87V Multimeter Price in Pakistan
Fluke 87V
Overview:
When productivity is on the line and you need to solve
problems fast, the Fluke 87V delivers the accuracy and advanced troubleshooting
capabilities you need. Designed specifically to handle complex signals, the 87V
industrial multimeter, allows you to gain productivity by taking the guesswork
out of drive system troubleshooting even in loud, high energy, and high
altitude locations.
Accurate frequency measurements on adjustable speed drives
(ASD) due to Fluke-designed low-pass filter
Built-in thermometer allows temperature measurements without
a separate thermometer
Peak Min/Max allows capture of intermittents as fast 250 µS
Dual display resolution – 6000 or 20,000 counts – lets you
see small changes in displayed readings
CAT III 1000V, CAT IV 600V safety rated
Features:
Unique function for accurate voltage and frequency
measurements on adjustable speed motor drives and other electrically noisy
equipment
Built-in thermometer conveniently allows you to take
temperature readings without having to carry a separate instrument
Optional magnetic hanger for easy set-up and viewing while
freeing your hands for other tasks
Large digit display with bright, two-level backlight makes
the 87V significantly easier to read than older models
True RMS AC voltage and current for accurate measurements on
non linear signals
Selectable filter for accurate voltage and frequency
measurements on motor drives
0.05% DC accuracy
6000 counts, 3-3/4 digits
4-1/2 digit mode for precise measurements (20,000 counts)
Measure up to 1000 VAC and DC
Measure up to 10 A, 20 A for up to 30 seconds
Built in thermometer lets you carry one less tool (TC probe
included)
Frequency to 200 kHz and % duty cycle
Resistance, continuity and diode test
10,000 µF capacitance range for components and motor caps
Min/Max-Average recording with Min/Max Alert to capture
variations automatically
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead interference from low ohms
measurements
Auto and manual ranging for maximum flexibility
Touch Hold to capture stable readings avoiding noisy signals
Large display digits and two-level bright white backlight
for increased visibility
Analog bargraph for fast changing or unstable signals
Input Alert provides audible warning against wrong use of
input jacks
Improved selectable sleep mode for long battery life
Access door for fast battery changes without breaking the
calibration seal
"Classic" design with new removable holster with
built in test lead and probe storage
Specifications: |
||
Voltage DC |
Maximum voltage |
1000 V |
Accuracy |
±(0.05% + 1) |
|
Maximum resolution |
10 µV |
|
Voltage AC |
Maximum voltage |
1000 V |
Accuracy |
±(0.7% + 2) True RMS |
|
AC bandwidth |
20 kHz with low pass
filter; 3 db @ 1 kHz |
|
Maximum resolution |
0.1 mV |
|
Current DC |
Maximum amps |
10 A (20 A for 30
seconds maximum) |
Amps accuracy |
±(0.2% + 2) |
|
Maximum resolution |
0.01 µA |
|
Current AC |
Maximum amps |
10 A (20 A for 30
seconds maximum) |
Amps accuracy |
±(1.0% + 2) True RMS |
|
Maximum resolution |
0.1 µA |
|
Resistance |
Maximum resistance |
50 MΩ |
Accuracy |
±(0.2% + 1) |
|
Maximum resolution |
0.1 Ω |
|
Capacitance |
Maximum capacitance |
9,999 µF |
accuracy |
±(1% + 2) |
|
Maximum resolution |
0.01 nF |
|
Frequency |
Maximum frequency |
200 kHz |
Accuracy |
±(0.005% + 1) |
|
Maximum resolution |
0.01 Hz |
|
Duty cycle |
Maximum duty cycle |
99.9% |
Accuracy |
±(0.2% per khz +
0.1%) |
|
Maximum resolution |
0.1% |
|
Temperature
measurement |
–200.0°C – 1090°C |
|
80 BK temperature
probe |
–40.0°C – 260°C |
|
Conductance |
Maximum conductance |
60.00 nS |
Accuracy |
±(1.0% + 10) |
|
Maximum resolution |
0.01 nS |
|
Diode |
Range |
3 V |
Resolution |
1 mV |
|
Accuracy |
±(2% + 1) |
|
Duty cycle range |
Accuracy |
Within ±(0.2% per
kHz + 0.1%) |
Environmental
Specifications |
||
Operating
temperature |
–20°C to + 55°C |
|
Storage temperature |
–40°C to + 60°C |
|
Humidity (without
condensation) |
0% – 90% (0°C –
35°C) |
|
Operating Altitude |
2000 m |
|
Safety
Specifications |
||
Overvoltage category |
EN 61010–1 to 1000 V
CAT III, 600V CAT IV |
|
Agency approvals |
UL, CSA, TÜV, VDE
listed |