Features
• Bandwidth 1000Hz
• True RMS
• Relative value measurement
• LED light
• Flashlight
• Duty cycle
• Inrush current
• Overload protection
• Diode
• On/off
• NCV (non-contact voltage detection)/Live (live wire identification)
• Maximum display 6000
• Insulation level CAT III 600V
• Opening size 23mm
• Automatic shutdown/data retention/backlight/unit display
• Power supply: 1.5V AAA*3
Function | Measuring range | precision |
resistance | 600Ω | ±(1.0%+10) |
6KΩ, 60KΩ, 600KΩ, 6MΩ | ±(0.8%+5) | |
60MΩ | ±(2.0%+10) | |
DC voltage | 600mV | ±(0.5%+3) |
6V, 60V, 600V | ±(0.8%+5) | |
1000V | ±(1.0%+5) | |
AC voltage | 600mV | ±(1.0%+10) |
6V, 60V, 600V | ±(1.0%+5) | |
750V | ±(1.2%+5) | |
DC | 60A, 600A, 1000A | ±(2.5%+10) |
Alternating current | 60A, 600A, 1000A | ±(2.5%+10) |
frequency | 10Hz ~ 10MHz | ±(0.5%+2) |
capacitance | 10nF | ±(4.0%+25) |
100nF, 1uF, 10uF, 100uF | ±(4.0%+15) | |
1mF, 10mF | ±(5.0%+25) | |
℃ | -20 ℃ ~0 ℃ | ±(5.0%+4) |
0 ℃ ~ 400 ℃ | ±(2.0%+3) | |
400 ℃ ~1000 ℃ | ±(3.0%+3) | |
℉ | -0 ℉ ~ 50 ℉ | ±(5.0%+4) |
50 ℉ ~ 750 ℉ | ±(2.0%+3) | |
750 ℉ ~1800 ℉ | ±(3.0%+3) |