"All prices are subject to change without prior notice due to currency fluctuation Please confirm prices before placing the order to avoid any confusion"
SOLD OUT Fluke 116C In Pakistan

Fluke 116C In Pakistan

Fluke 116C


Specifications

Maximum voltage between any terminal and earth ground
 600 V
Surge protection
 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:6,000 counts, updates 4 per second
Bar graph
 33 segments, updates 32 per second
Operating Temperature
 -10 °C to + 50 °C
Storage Temperature
 -40 °C to + 60 °C
Battery type
 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
 400 hours typical, without backlight

 

Accuracy Specifications

DC millivolts
Range:600.0 mV
Resolution:0.1 mV
Accuracy:± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:6.000 V / 0.001 V
Range/Resolution:60.00 V / 0.01 V
Range/Resolution:600.00 V / 0.1 V
Accuracy:± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:600.0 V
Resolution:0.1 V
Accuracy:2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1true-rms
Range:600.0 mV
Resolution:0.1 mV
Accuracy:1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:6.000 V / 0.001 V
Range/Resolution:60.00 V / 0.01 V
Range/Resolution:600.0 V / 0.1 V
Accuracy:1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:600 Ω
Resolution:1 Ω
Accuracy:Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:600.0 Ω / 0.1 Ω
Range/Resolution:6.000 kΩ / 0.001 kΩ
Range/Resolution:60.00 kΩ / 0.01 kΩ
Range/Resolution:600.0 kΩ / 0.1 kΩ
Range/Resolution:6.000 MΩ / 0.001 MΩ
Accuracy:0.9 % + 1
Range/Resolution:40.00 MΩ / 0.01 MΩ
Accuracy:1.5 % + 2
Diode Test
Range/Resolution:2.000 V / 0.001 V
Accuracy:0.9% + 2
Capacitance
Range/Resolution:1000 nF / 1 nF
Range/Resolution:10.00 μF / 0.01 μF
Range/Resolution:100.0 μF / 0.1 μF
Range/Resolution:9999 μF / 1 μF
Range/Resolution:100 μF to 1000 μF
Accuracy:1.9% + 2
Range/Resolution:> 1000 μF
Accuracy:5% + 20%
LoZ capacitance
Range:1 nF to 500 μF
Accuracy:10% + 2 typical
Temperature2(Type-K thermocouple)
Range/Resolution:-40 °C to 400 °C / 0.1 °C
Accuracy:1% + 102
Range/Resolution:-40 °F to 752 °F / 0.2 °F
Accuracy:1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:600.0 μA / 0.1 μA
Accuracy:1.0% + 2
DC μamps
Range/Resolution:600.0 μA / 0.1 μA
Accuracy:1.0% + 2
Hz (V or A input)2
Range/Resolution:99.99 Hz / 0.01 Hz
Range/Resolution:999.99 Hz / 0.1 Hz

Fluke 116C In Pakistan

  • Views: 1893
  • Product: True-RMS Digital Multimeter
  • Availability: SOLD OUT
  • Rs 45,500
  • + Rs 300 Shipping charges:
whatsapp

Tags: fluke 116c, Fluke 116C In Pakistan, Fluke 116C Price In Pakistan, Fluke 116C In Islamabad, Fluke 116C In Karachi, Fluke 116C In Lahore, Fluke 116C Price 2022, Fluke 116C 2022, multimeters, true-rms, digital