Main Menu / Categories
Your Cart

FLUKE 393FC

FLUKE 393FC
New
Tags: FLUKE 393FC
FLUKE 393FC
  • Stock: In Stock
  • Model: Solar Clamp Meter CAT III 1500 V
160,000
+ 1,000 Shipping charges

Features

  • IP54 rated, ideal for work outdoors in dusty or damp conditions on solar arrays and wind power systems
  • DC power measurement, showing readings in kVA
  • Audio polarity indicator helps prevent accidental miswires
  • Visual continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Logging and reporting of test results via software
  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cables
  • MC4 test lead sets are designed for use with solar clamp meters that accept 0.15" (4 mm) banana plugs, rated to CAT III 1000 V / CAT IV 600 V
  • View voltage and current simultaneously with the meter's dual display

Applications

  • Solar arrays
  • Wind power
  • Electric railways
  • Data centers
  • Battery Banks for uninterruptible power supplies


Fluke 393FC Specifications

Maximum Voltage Between Any Terminal and Earth Ground1000 V AC
1500 V DC
Electrical SpecificationsAccuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C)
AC Current: JawRange: 999.9 A
Resolution: 0.1 A
Accuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz)

Crest factor (50/60 Hz):
2.5 at 600 A
3 at 500 A
1.42 at 999.9 A
Add 2% for C.F. >2
AC Current: Flexible Current ProbeRange: 999.9 A; 2500 A
Resolution: 0.1 A (≤999.9 A); 1 A (≤2500 A)
Accuracy: 3 % RD + 5 digits (10 to 500 Hz)Crest factor (50/60Hz):
2.5 at 1400 A
3 at 1100 A
1.42 at 2500 A
Add 2% for C.F. >2
Position SensitivityDistance from optimum:
A
B
C

i2500-18 Flex:
1.4" (35.6 mm)
2" (50.8 mm)
2.5" (63.5 mm)

Error:
±0.5%
±1%
±2%
DC CurrentRange: 999.9 A
Resolution: 0.1 A
Accuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsets
AC VoltageRange: 600 V; 1000 V
Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
Accuracy: 1% RD + 5 digits (20 to 500 Hz)
DC VoltageRange: 600 V; 1500
Resolution: 0.1 V (≤600 V), 1 V (≤1500 V)
Accuracy: 1% RD + 5 digits
mV DCRange: 500 mV
Resolution: 0.1 mV
Accuracy: 1% RD + 5 digits
Amps Frequency: JawRange: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Amps Frequency: Flexible Current ProbeRange: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Voltage FrequencyRange: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 20 Hz, ≥5 V
20 to 100 Hz, ≥5 V
100 to 500 Hz, ≥10 V
DC PowerRange: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range)
Resolution: 0.1 kVA, 1 kVA
Accuracy: 2% RD + 2 kVA, 2% RD + 20 kVA
ResistanceRange: 600 Ω, 6000 Ω, 60 kΩ
Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ)
Accuracy: 1% RD + 5 digits
CapacitanceRange: 100 μF, 1000 μF
Resolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF)
Accuracy: 1% RD + 5 digits
Inrush trigger level: 5 A
TemperatureOperating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)