Designed with your on-the-job needs in mind, the new
Fluke 62 MAX and 62 MAX+ infrared thermometers are everything you’d
expect from the experts in measurement tools. Small in size, extremely
accurate and very easy to use. IP54 rated for dust and water resistance.
Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and
62 MAX+ are so tough, they’re the only IR thermometers around you can
handle without care.
Features:
Key Benefits
Dust
and water-resistant: IP54 rated for dust and water resistance.
Rugged:
3-meter (9.8-foot) drop tested.
Ergonomically
designed: Completely redesigned for a more natural hand fit.
Small
and lightweight; clips to your tool belt or belt loop or easily fits
into your tool box.
Additional
Features
Distance
to spot: Precise laser technology makes for more accurate and repeatable
measurements.
Dual
lasers: The 62 MAX+ has dual rotating lasers to help you identify area
to be measured. The measurement area is the spot between the dots.
Large,
backlit display: Large screen makes data easier to read, even in dark
areas.
Min/Max/Avg/Dif:
Displays the minimum, maximum or average temperature, or the difference
between two measurements.
Alarm:
Hi and Lo alarms for rapid display of measurements outside the limits.
Power:
Both the 62 MAX and 62 MAX+ are powered by a single, standard AA
battery.
Specifications
Temperature Range
Fluke 62 MAX
-30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62 MAX+
-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX
±1.5 °C or ±1.5% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Fluke 62 MAX+
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX
<500 ms (95% of reading)
Fluke 62 MAX+
<300 ms (95% of reading)
Spectral Response
8 to 14 microns
Emissivity
0.10 to 1.00
Optical Resolution
Fluke 62 MAX
10:1 (calculated at 90% energy)
Fluke 62 MAX+
12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX
±0.8% of reading or <±1.0 °C (2 °F), whichever is
greater
Fluke 62 MAX+
±0.5% of reading or <±0.5 °C (1 °F), whichever is
greater
Power
AA battery
Battery Life
Fluke 62 MAX
10 hours with laser and backlight on
Fluke 62 MAX+
8 hours with laser and backlight on
Physical Specifications
Weight
255 g (8.99 oz)
Size
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity
10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude
2000 meters above mean sea level
Storage Altitude
12,000 meters above mean sea level
IP Rating
IP 54 per IEC 60529
Drop Test
3 meters
Vibration and Shock
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms