"All prices are subject to change without prior notice due to currency fluctuation Please confirm prices before placing the order to avoid any confusion"
New PREORDER

GF6018A GFUVE

This GF6018A high precision multi-product calibrator is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05% single-phase standard AC/DC voltage and current source, can verify level 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter & clamp meter. The source signals by using DSP and 16-bit high-speed A/D converters of controllable sine wave, the distorted wave signal source. Multifunction calibrator GF6018A is designed as universal calibration tool for electrical calibration laboratories.


DESCRIPTION

The GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected with PC to control, become automatic verification system. It has precise interface and multi-functions including verification, storage and query. The GF6018A multimeter calibrator adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics. It fully meets ISO17025 laboratory standards and is a good ideal test equipment for electrical engineers.


PARAMETERS

Electrical parameters
Power supplySingle phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Voltage output
range200mV, 400mV, 2000mV, 4000mV,
20V, 100V, 200V, 500V, 1000V; max 1050V
Range 20V-1000VAccuracy±(0.03%RD+0.02%FS)
Stability≤0.01% FS /60s
Range 200mV-4000mVAccuracy±(0.3%RD+0.2%FS)
Stability≤0.04% FS /60s
Load capacity20VA
Waveform distortion≤0.3%
Adjustable Range0-120% FS (1000V not included)
Fineness5×10-5
AC Current Output
Range2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A; max 24A
Range 0.2A-20AAccuracy±(0.03%RD+0.02%FS)
Stability≤0.01% FS /60s
Range 2mA-40mAAccuracy±(0.3%RD+0.2%FS)
Stability≤0.04% FS /60s
Load capacity20VA
Waveform distortion≤0.3%
Adjustable Range0-120% FS
Fineness5×10-5
Frequency Output
Range45-65Hz
Fineness0.001Hz
Accuracy0.002Hz
Harmonic Wave
Times2-31
Extent0-20%
Each harmonic phase fineness0.01·N (N is harmonic order)
DC voltage output
Range200mV, 400mV, 2000mV, 4000mV,
20V, 40V, 100V, 200V, 400V, 1000V; max 1050V
Load capacity20W
Adjustable range0-110% FS (1000V not included)
Adjustable fineness5×10-5
Stability≤0.01% FS /60s (peak-peak value)
Accuracy±(0.03%RD+0.02%FS)
Ripple wave≤1% FS
DC current output
Range20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A; max 22A
Load capacity20W
Adjustable Range0-110% FS (1000V not included)
Adjustable Fineness5×10-5
Stability≤0.01% FS /60s (peak-peak value)
Accuracy±(0.06%RD+0.04%FS)
Ripple wave≤1% FS
Resistance box
Range10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10 kΩ, 20kΩ, 50KΩ, 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ, 5MΩ, 10MΩ, 20MΩ
Fineness0.02%
Adjustable Range0-100%FS
Accuracy±(0.3%RD+0.2%FS)
Clamp meter range
200AAccuracy±0.2%
600AAccuracy±0.5%
1000AAccuracy±1%
Dot frequency square wave output
Range1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
Square wave amplitude4.5V
Setting accuracy5×10-5
Communication Port
Communication PortRS232, USB
Standard
StandardJJG124-2005; JJF1587-2016; IEC61010, IEC 61000, IEC 61326
Safety
Isolation protectionIEC 61010-1:2001
Measurement Category300 V CAT III, 600 V CAT II
Degree of protectionIP20
Declaration of conformityCE, CNAS certified
Mechanical parameters
Dimension (L×W×H) (mm)440x360x160
Weight (kg)12
Environmental conditions
Operating temperature20°C±10°C
Storage conditions-30°C to 60°C
Relative humidity≤85%RH
(1) FS means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

GF6018A GFUVE

  • Views: 213
  • Product: CLAMP TYPE MULTIMETER CALIBRATOR
  • Availability: PREORDER
  • Rs 2,950,000
  • Free Shipping
whatsapp

Tags: gf6018a, gfuve, calibration, tools, clamp, type, multimeter, calibrator