MS6818 Mastech Advanced Wire Tracker In Pakistan
MS6818 Mastech Advanced Wire Tracker In Pakistan
- Stock: In Stock
- Model: Advanced Wire Tracker
34,300
The MASTECH MS6818 Underground Wire Cable Metal Pipe Locator Detector Tester consists of a signal transmitter and a receiver, widely used in the construction and maintenance of communication cables, power cables, metal pipes, and much more. Current and voltage conducting cables, electrical circuits, conduits, water and heating pipelines, fuses, switches can all be located. Short circuits and interruptions of assorted lines and cables can be detected. Even better, the detection is possible not only underground but also in walls and concrete.
Technical Parameters of Transmitter
- Power supply: 1*9V 6F22 Battery
- Product size: 190mm*89mm*42.5mm/7.48"*3.5"*1.67"
- Product weight: 420g/0.92Ib
- Safety rating: CE(EMC+LVD) ETL CAT.III 300V RoHS
Technical Parameter of Receiver
- Power supply: 1*9V 6F22 Battery
- Product size: 241.5mm*78mm*38.5mm/9.5"*3"*1.5"
- Product weight: 350g/0.77Ib
- Safety rating: CE(EMC+LVD) ETL CAT.III 300V RoHS
- Find the Beaks or Shorts in Cable in the wall or Earth
- Track Cables in the wall or Earth
- Find the Fuse and Safeguard
- Find the Beaks or Shorts in Conduit under the Floor
- Track a Metal Conduit in the Project of ware or hot
- Sensitivity of Receiver can be Selected
- Auto Ranging, Auto Power Off, Backlight and Worklight
Technical Parameters of Transmitter |
Output Signal | 125kHz |
External Voltage | DC 12~400V AC 12~400V (50~60Hz)+-2.5% |
Fuse | F 0.5A 500V |
MIN Current | about 31mA |
MAX Current | about 115mA |
In Work | 0~40℃, with MAX relative humidity of 80% |
In Storage | -20~60℃, with MAX relative humidity of 80% |
Altitude | <2000m |
Technical Parameters of Receiver |
Depth of Tracking | The Depth of Tracking Depends on the Material and Specific Applications |
Cable Locating Mode | Single pole application : about 0~2m |
Dual pole application : about 0~0.5m | |
Single loop line : Up to 2.5m | |
MIN Current | about 32mA |
MAX Current | about 89mA |
In Work | 0~40℃, with MAX relative humidity of 80% |
In Storage | -20~60℃, with MAX relative humidity of 80% |
Altitude | <2000m |