ANENG ST209 Digital Multimeter Clamp Meter 6000 counts True RMS Amp DC/AC Current Clamp tester Meters voltmeter 400v Auto Range

Product Description

Feature:

1-1.Display: liquid crystal display (LCD);

1-2. Maximum display: 5999 (35/6) bit automatic polarity display;

1-3. Measurement method: double integral A/D conversion;

1-4. Sampling rate: about 3 times per second;

1-5. Overrange display: The highest position shows"OL";

1-6.Low voltage display:"Low voltage symbol"symbol appears;

1-7.Working environment:(0~40)°,relative humidity<80%;

1-8.Power: AAA 1.5V battery(notincluida);

Function:

DC voltage DCV YES AC voltage ACV YES

DC current DCA YES AC current ACA YES

Resistor / Diode /On-Off Test / Capacitor YES

Square wave output YES NCV YES

Zero line /Fire line test - Full unit symbol YES

Frequency F YES True RMS measurement YES

Temperature(°/°) YES Flashlight lighting YES

Backlight manual/Auto off YES

Range Accuracy Resolution

DC voltage 6V/60V/600V ± (0.8% + 10) 0.001V/ 0.01V/0.1V

DC voltage 1000V ±(0.5%+3) 1V

AC voltage 6V/60V/600V ± (0.8% +3) 0.001V/ 0.01V/0.1V

AC voltage 750V ± (1.2% +10) 1V

DC current 60A/600A ± (2.5% +30) 0.01A/0.1A

AC current 60A/600A ± (2.5% +30) 0.01A/0.1A

Resistance (omh) 600 ± (0.8% + 5) 0.1

Resistance (omh) 6K/60K/600K/6M ± (0.8% + 3) 1/10/100/1k

Resistance (omh) 40M ± (2.5% + 3) 10k

Capacitance(C) 60nF/600nF/6uF/60uF/600uF ± (3.5% + 20) 10pF/100pF/1nF/10nF/100nF

Capacitance(C) 6mF/30mF ± (5% + 3) 1uF/10uF

Frequency 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz ± (0.1% + 3)

0.01Hz/0.1Hz/1Hz/10Hz/100Hz/1kHz/10kHz

Temperature (-20-1000℃) As the instructions 1℃

(0-1832℉) As the instructions 1℉

Package:

1* instruction manual,

1* certificate, one leather cas

1* pair of test leads,

1* temperature probe,

NOTE:

This series of instruments is designed in accordance with IEC1010 (Safety Standards promulgated by the International Electrotechnical Commission), please read the safety precautions before use.

1. When measuring voltage, please do not input the limit voltage exceeding the effective value of DC