Fluke 1AC-C2 Price In Pakistan

- Stock: In Stock
- Model: Non-Contact Voltage Alert Detector Pen
Buy Now Fluke 1AC II Non-Contact Voltage Tester At Best Price In Pakistan 2025
Key Features
Tip glows red and beeper sounds when voltage is detected
Continuous self-test ensures proper functionality
Voltage detection range options: 90–1000 V AC or 200–1000 V AC
Audible/Silent mode for use in different environments
Pocket-sized for quick, convenient testing
Suitable for electricians, maintenance staff, safety teams, and homeowners
Product Overview
The Fluke 1AC II is a compact, easy-to-use non-contact voltage detector. Touch the tester's tip to a terminal, outlet, or cord to check for voltage. When voltage is present, the tip glows red and the tester beeps.
Ideal for identifying energized circuits, verifying power presence, and detecting wiring issues in homes, commercial spaces, and industrial environments.
Detection and Alerts
Bright red tip indicator signals voltage presence
Audible beeper provides clear sound alert
Beeper can be disabled for quiet environments
Self-Test and Reliability
Continuous self-test confirms the unit is operational
Blinking red tip indicates the tester is active and functioning
Voltage Range and Applications
Standard models: 90–1000 V AC or 200–1000 V AC
Suitable for a wide range of residential, commercial, and industrial uses
Also available in a low-voltage variant: 20–90 V AC
Safety Features
Rated CAT IV 1000 V for maximum safety
CE and CSA certified
Additional Features
Audible/Silent mode
On/Off control
Supplied with batteries
Two-year warranty
Specifications
Operating Principle
Senses the steady electrostatic field produced by AC voltage through insulation without requiring direct conductor contact. A red glow and audible tone (when enabled) indicate voltage presence.Voltage Sensing Range
90 V AC to 1000 V AC (nominal)Detector Tip
Flat-tip designLight Source
High-intensity red LEDSafety and Compliance
IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 1000 V
EMC: IEC 61326-1 Portable
IP40 ingress protection
Environmental Conditions
Operating Temperature: -10°C to 50°C
Operating Humidity:
0%–95% (0°C–30°C)
0%–75% (30°C–40°C)
0%–45% (40°C–55°C)
Operating Altitude: up to 3000 m
Maintenance
Clean with a damp clothPower
Two AAA alkaline batteries (included)
Typical battery life: Over 1 year