Main Menu / Categories
Your Cart

KEW2431 KYORITSU

KEW2431 KYORITSU
Pre-Order

Frequency Selector Switch to eliminate the effect of harmonics

  • Frequency Selector Switch to eliminate the effect of harmonics
  • Auto power-off function
  • Rotary switch for easy one finger power on and range selection
  • Minimum resolution 0.01m

    Specification

  • AC A (50/60Hz)
  • 20/200mA/200A
    ±3%rdg±5dgt (20/200mA/100A)
    ±5%rdg±5dgt (200A)
  • AC A (WIDE)
  • 20/200mA/200A
    ±2%rdg±4dgt [50/60Hz] (20/200mA/0 to 100A)
    ±5%rdg±6dgt [40 to 400Hz] (20/200mA/0 to 100A)
    ±5%rdg±4dgt [50/60Hz] (100.1 to 200A)
  • Conductor size
  • φ24mm max.
  • Frequency response
  • 40 to 400Hz
  • Effect of external stray magnetic field φ15mm 100A
  • 10mA AC max.
  • Safety Standard
  • IEC 61010-1 CAT III 300V
    IEC 61010-2-032
  • Power source
  • LR44 (1.5V)× 2
  • Dimension
  • 149(L)× 60(W) × 26(D)mm
  • Weight
  • Approx. 120g (including battery)