LB06 BRIGHTWIN

- Stock: Pre-Order
- Model: Multifunction Process Calibrator
LB06 Multifunction Process Calibrator with Hart Modbus
Function
at the Best price in Pakistan
Description
BRT LB06 Process calibrator can be used as a high precision
mV mA calibrator, 4-20mA loop calibrator, temperature calibrator, frequency
calibrator, Hart operator, Modbus Master/Slave meter, digital multimeter, etc.
It is an upgrade premium version of It covers all the functions of LB02 process
calibrator and add frequency, Hart, Modbus function, etc. Its accuracy is up to
0.025%, its button has corresponding function description, user can use it
without difficulties. Inside the LB06 process calibrator, there are high
precision AD, DA chips, highly efficient circuits used to ensure its high
accuracy and stable performance. This multifunction process calibrator is an
ideal low-cost high precision process controlling signal calibrator with
multimeter.
Main Features
● High Precision 0.025%+1/2 digits, high reliability & stability in signal
output and measurement.
● User friendly design, pocket size: 122 x 80 x 27mm, put it into your pocket,
save energy, save cost.
● Output simulation: 0/4-20mA source/passive, 0-11V, 0-110mV, 20-400Ω, R, E, S,
K, J, B, T, N type thermocouple, PT1000, PT100, CU50, 24V outputs, frequency,
etc.
● Measurement: -30-+30V, -150- +150mV, -30mA to +30mA, 0-999.9Ω, R, E, S, K, J,
B, T, N type thermocouple, PT100, Pt1000 CU50, 24V, 0-24mA, Ohm, frequency,
etc.
● Signal generator, multifunction process calibrator and digital multimeter
all-in-one.
● Have standard MODBUS Master, MODBUS Slave, Hart communicator or operator
function.
● Have description in V, mV, mA, RTD, TC, Step, Ω, Hz, MODBUS, Hart keys, use
it easily.
● Have automatic output mode, manual output mode, customized output mode,
signal conversion, curves output, full function operation, etc.
● High resolution color LCD display with back light for different lighting
conditions, large screen clear display.
● Fast response, no delay in signal source simulation and signal testing or
measurement.
● Have battery capacity bar to check the battery status easily.
● Precision AD, DA, reference voltage, OP circuits are used to ensure high
accuracy, high performance and high stability.
● Have 4 units of PPTC and a quick-break fuse to protect the instrument from
damaged by high voltage.
Output Parameters
FUNC | OUT
UNIT | RANGE | SET
STEP | ACCURACY
(SP: setting point) |
DC.
V | V | 0~11.00V | 0.01/0.1/1 | ±0.025%SP
±0.004V |
DC.
mV | mV | 0~110.00mV | 0.1/1/10 | ±0.025%SP
±0.03mV |
DC.
mA | Sink/Source/Program | 0~24.00mA | 0.01/0.1/1/4 | ±0.025%SP
±0.004mA |
Ohm | Ω | 0~400Ω | 1/10/100 | ±0.025%SP
±0.3Ω |
400~2200Ω | 1/10/100 | ±0.05%SP
±1.5Ω | ||
Frequency | KHz | 0-10 | 0.01/0.1/1 | ±0.05%SP
±2Hz |
TC | R | 0~1700℃ | 1/10/100 | ±0.1%SP
±3℃ |
S | 0~1600℃ | |||
B | 500~1800℃ | |||
K | -200~1370℃ | ±0.05%SP
±0.5℃(K) ±0.05%SP
±0.3℃(E) ±0.05%SP
±0.4℃(J) ±0.05%SP
±0.5℃(T) ±0.05%SP
±0.8℃(N) | ||
E | -200~1000℃ | |||
J | -200~1200℃ | |||
T | -200~400℃ | |||
N | -200~1300℃ | |||
RTD | Pt1000 | -50~300℃ | 1/10/100 | ±0.1%SP±0.5℃ |
Pt100 | -200~850℃ | ±0.1%SP
±0.8℃ | ||
Cu50 | -50~150℃ | ±0.1%SP±1.5℃ | ||
24V | 24V mA | 24V:
Cannot be set. Current measurement:0~24.000 mA | NONE |
Measurement Parameters
FUNC | UNIT | RANGE | RESOLUTION | ACCURACY
(RD: Read number) |
V | V | -30~30.000V | 0.001V | ±0.025%RD
±0.004V |
DC.
mV | mV | -150~150.00mV | 0.01mV | ±0.025%RD
±0.02mV |
DC.
mA | mA | -30~30.000mA | 0.001mA | ±0.025%RD
±0.004mA |
Ohm | Ω | 0~999.9Ω | 0.1Ω | ±0.025%RD
±0.2Ω |
1000-2500 | 1Ω | ±0.025%RD
±1Ω | ||
Frequency | KHz | 0-10 | 0.001 | ±0.05%RD
±2Hz |
TC | R | 0~1700℃ | 0.1℃ | ±0.1%RD
±3℃ |
S | 0~1600℃ | |||
B | 500~1800℃ | |||
K | -200~1370℃ | ±0.025%RD
±0.5℃(K) ±0.025%RD
±0.3℃(E) ±0.025%RD
±0.4℃(J) ±0.05%RD
±0.5℃(T) ±0.025%RD
±0.8℃(N) | ||
E | -200~1000℃ | |||
J | -200~1200℃ | |||
T | -200~400℃ | |||
N | -200~1300℃ | |||
RTD | Pt1000 | -50~300℃ | 0.1℃ | ±0.1%RD
±0.5℃ |
Pt100 | -200~850℃ | ±0.1%RD
±0.8℃ | ||
Cu50 | -50~150℃ | ±0.1%RD
±1.5℃ | ||
Range
switch | mA | 0~9990
engineering unit (for current measurement and measure the current of 24V
output) | Max. 4,
Min. 1 (related to engineering quantity.) |