KEW6011A KYORITSU

KEW6011A KYORITSU
Pre-Order
KEW6011A KYORITSU
  • Stock: Pre-Order
  • Model: MULTI FUNCTION INSTALLATION TESTER

Complies with IEC 61557

  • Complies with IEC 61557
  • Designed to IP 54 Rating
  • Live circuit and wiring connection check LED's
  • Triple ranges insulation tests at 250, 500 and 1000V
  • Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip)
  • Phase angle selection on RCD ranges
  • Polarity switch for continuity tests
  • Auto-null facility for continuity tests
  • Earth probe for loop impedance testing on extraneous metalwork
  • Contact Voltage Reading
  • Test of a large kind of RCD's: Standard, Selective, AC and A
    (DC sensitive breakers)

    Specification

  • Continuity Testing
  • Measuring Ranges
  • 20/200/2000Ω (Auto-ranging)
  • Open Circuit Voltage
  • >6V
  • Short Circuit Current
  • >200mA DC
  • Accuracy
  • ±(1.5%rdg+3dgt)
  • Insulation Testing
  • Measuring Ranges
  • 20/200MΩ (Auto-ranging)
  • Test Voltage
  • 250V 500V 1000V DC
  • Output Voltage on Open Circuit
  • 250V+40 to 0%
    500V+30 to 0%
    1000V+20 to 0%
  • Rated Current
  • > 1mA
  • Accuracy
  • ±(1.5%rdg+3dgt)
  • Loop Impedance Testing
  • Rated Voltage
  • 230V AC +10 to 15% [50Hz]
  • Voltage Measuring Range
  • 100 to 250V AC [50Hz]
  • Impedance Ranges
  • 20/200/2000Ω
  • Nominal Test Current
  • 25A (20Ω range) 15mA (200Ω range) 15mA (2000Ω range)
  • Accuracy
  • 20Ω range ±(3%rdg +4dgt)
    200Ω range ±(3%rdg +8dgt)
    2000Ω range ±(3%rdg +4dgt)
  • PSC Testing
  • Rated Voltage
  • 230V AC +10 to 15% [50Hz]
  • PSC Ranges
  • 200A (15mA Test Current)
    2000A (25A Test Current)
    20kA (25A Test Current)
  • Accuracy
  • PSC accuracy derived from measured loop impedance specification
    and measured voltage specification
  • RCD Testing
  • Rated Voltage
  • 230V AC +10 to 15% [50Hz]
  • Trip Current Settings
  • RCD × 1/2 : 10,30,100,300,500,1000mA
    RCD × 1 : 10,30,100,300,500,1000mA
    RCD × 5 : 10,30,100,300mA (on × 5 ranges max current 1A)
  • Trip Current Duration
  • RCD × 1/2 × 1: 2000ms
    RCD fast: 50ms
  • Accuracy
  • Trip current +10 to 0% of test current at 230V
    Trip time ±(1%rdg + 3dgt)
  • Applicable standards
  • IEC 61010-1 CAT 300V Pollution Degree 2, IEC 61010-2-034, IEC 61557
  • Power source
  • R6/LR6 × 8
  • Dimension
  • 130(L) × 183(W) × 100(D)mm
  • Weight
  • Approx. 1100g
  • Accessories
  • KAPM10 (Test lead with IEC connecter)*1
    7122B (Test leads)
    7132A (External earth probe)
    8923 (Fuse[0.5A/600V]) × 1 (included), 1 (spare)
    9092(Cord case)
    9121 (Shoulder Strap)
    R6(AA) × 8 Instruction Manual