Main Menu / Categories
Your Cart

KEW4106 KYORITSU Price In Pakistan

Buy Now KEW4106 KYORITSU At Best Price In Pakistan 2025.

Earth Resistance & Resistivity Tester

  • Earth resistance measurement with six ranges covering measurements from 0.001 Ω to 200 kΩ
  • Earth resistivity (ρ) measurement is automatically calculated after having set the distance between Auxiliary Earth Spikes (Wenner method)
  • Automatic and Manual selection of the Test Current Frequency in four bands of 94/105/111/128Hz
    In Automatic mode KEW 4106 will select the most suitable Frequency
  • Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements
  • Up to 800 measurement results can be saved in the memory and recalled on the display
  • The stored results can be transferred to a PC by using USB adapter (MODEL 8212-USB) and the special software "KEW Report"
  • Robust design with IP54 protection

https://testinstruments.pk/kew4106-kyoritsu



  • Function
  • Range
  • Resolution
  • Measuring range
  • Accuracy
  • Earth resistance
    Re
    (Rg at
    ρ measurement)
  • 0.001Ω
  • 0.03 to 2.099Ω
  • ±2%rdg±0.03Ω
  • 20Ω
  • 0.01Ω
  • 0.03 to 20.99Ω
  • ±2%rdg±5dgt (*1)
  • 200Ω
  • 0.1Ω
  • 0.3 to 209.9Ω
  • 2000Ω
  • 3 to 2099Ω
  • 20kΩ
  • 10Ω
  • 0.03 to 20.99kΩ
  • 200kΩ
  • 100Ω
  • 0.3 to 209.9kΩ
  • Auxiliary earth resistance
    Rh, Rs
  • 8% of Re+Rh+Rs
  • Earth resistivity
    ρ
  • 0.1 to 1Ω·m
    Auto-ranging
  • 0.2 to 395.6Ω·m
  • ρ=2×π×a×Rg (*2)
  • 20Ω
  • 0.2 to 3956Ω·m
  • 200Ω
  • 20 to 39.56kΩ·m
  • 2000Ω
  • 0.2 to 395.6kΩ·m
  • 20kΩ
  • 2.0 to 1999kΩ·m
  • 200kΩ
  • Series interference voltage
    Ust (A.C only) (*3)
  • 50V
  • 0.1V
  • 0 to 50.9Vrms
  • ±2%rdg±2dgt (50/60Hz)
  • ±3%rdg±2dgt (40 to 500Hz)
  • Frequency
    Fst
  • Auto-ranging
  • 0.1Hz
    1Hz
  • 40Hz to 499.9Hz
  • ±1%rdg±2dgt
  • Measuring method
  • Earth resistance: Fall-of-potential method
    (currents and voltages measured via the Probes)
    Measurement method of Earth Resistivity (ρ): Wenner 4-pole method
    Series interference voltage (earth voltage)
    RMS Rectifier (between the E-S Terminals)
  • Memory capacity
  • 800 data
  • Communication Interface
  • Model 8212-USB Optical Adapter
  • LCD
  • Dot-matrix 192×64 monochrome
  • Over-range Indication
  • "OL"
  • Overload Protection
  • between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
  • Applicable standards
  • IEC 61010-1 CAT 300V / CAT 150V Pollution degree 2
    IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
  • Power source
  • DC12V : sizeAA manganese dry battery (R6) × 8
    (Auto power off: Approx. 5 minutes)
  • Dimension
  • 167(L) × 185(W) × 89(D) mm
  • Weight
  • Approx. 900g (including batteries)
  • Accessories
  • 7229A (Earth precision measurement),
    7238A (Simplified measurement test leads),
    8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),
    8200-04 (Cord reel [4 pcs])×1 set,
    8212-USB (USB adapter),
    8923(Fuse [0.5A/600V]) × 1 (included), 1 (spare),
    9121 (Shoulder strap),
    9125 (Carrying case),
    R6 × 8, Instruction manual