Main Menu / Categories
Your Cart

KEW6305 KYORITSU

KEW6305 KYORITSU
Pre-Order

Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems

  • Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
  • Voltage, Current, Power Factor and Frequency measurements
  • Power analysis (Active, Apparent and Reactive power)
  • Energy analysis (Active, Apparent and Reactive energy)
  • Active power accuracy: ±0.3%rdg±0.2%f.s.
  • Automatic wiring check function to prevent incorrect connections
  • Large memory capability (2GB) using built-in SD card Interface
  • Recording interval can be set between 1 second and 1 hour
  • Real-time and remote measurements
  • Windows software for data analysis and setting via USB port or Bluetooth®
  • Synchronous measurements between two units of KEW 6305
  • Wide selection of clamp sensors allow measurements from 0.1 to 3000A
  • Automatic recognitions of connected sensor type
  • Double power supply system via AC line and batteries

    Specification

  • Wiring connections
  • 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
  • Measurements
  • Voltage, Current, Frequency, Active power
  • Parameters
  • Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Power factor (cos θ), Neutral current
  • Voltage range[RMS]
  • 150.0 / 300.0 / 600.0V
  • Voltage accuracy
  • ±0.2%rdg±0.2%f.s. (sine wave, 45 to 65Hz)
  • Current range[RMS]
  • 8128/8135 ( 50A type ) : 1.000 / 5.000 / 10.00 / 25.00 / 50.00A / AUTO
    8127 ( 100A type ) : 2.000 / 10.00 / 20.00 / 50.00 / 100.0A / AUTO
    8126 ( 200A type ) : 4.000 / 20.00 / 40.00 / 100.0 / 200.0A / AUTO
    8125 ( 500A type ) : 10.00 / 50.00 / 100.0 / 250.0 / 500.0A / AUTO
    8124/8130( 1000A type ) : 20.00 / 100.0 / 200.0 / 500.0 / 1000A / AUTO
    8133 ( 3000A type ) : 60.00 / 300.0 / 600.0 / 1500 / 3000A / AUTO
  • Current accuracy
  • ±0.2%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45 to 65Hz)
    +1%f.s. at the lowest range
  • Display range
  • 5 to 130% of each range(Voltage)
    1 to 130% of each range(Current)
  • Crest factor
  • Voltage: 2.5 or less, Current: 3.0 or less (max. 1.4Vpeak)
  • Active power accuracy
  • ±0.3%rdg±0.2%f.s.+ Accuracy of Clamp sensor
    +1%f.s. when the lowest current ranges is selected.
    *When measuring 3P3W system with 3P3W3A setting, distorted voltage or current may cause reading error in proportion to the magnitude of each distortion.
  • Effect of power factor
  • Active power: ±1.0%rdg cos θ=±0.5 (PF=1)
  • Frequency meter range
  • 40.0 to 70.0Hz
  • Frequency meter accuracy
  • ±3dgt
  • Accuracy precondition
  • PF=1, Sine wave, 45 to 65Hz, 23ºC±5ºC
  • Display update period
  • 1 second
  • Applicable standards
  • IEC 61010-1 CAT 600V
  • Operating temperature and humidity range
  • 0 to +50ºC, less than 85%RH (without condensation)
  • Storage temperature and humidity range
  • -20 to +60ºC, less than 85%RH (without condensation)
  • Power supply (AC Line)
  • AC100 to 240V±10% (45 to 65Hz)
  • Power supply (DC battery)
  • LR6 or Ni-MH (HR-15-51) ×6 (Battery charger not included), Battery life approx. 15h (LR6)
  • Power consumption
  • 10VA (max.)
  • Communication interface
  • USB, Bluetooth®5.0
  • PC card interface
  • SD card (2GB)
  • Dimension
  • 175(L)×120(W)×65(D) mm
  • Weight
  • Approx. 800g (including batteries)
  • Accessories
  •  (Voltage test lead set)
    (USB cable)
    (Power cord[EU]) or 7240(Power cord[UK])
    (SD card [2GB])
     (Carrying case)
    Battery (LR6)×6, Quick manual