Fluke 572-2 In Pakistan

- Stock: Pre-Order
- Model: High Temperature Infrared Thermometer -30 °C to 900 °C
Overview:
The Fluke 572-2 High-Temperature Infrared Thermometer is the
one product you can use in high-temperature industrial environments all around
the world. Whether you work in power utility, metal refining and smelting,
glass, cement or petrochemical environments, the 572-2 allows you to carry the
most trusted name in test tools anywhere you need accurate, high-temperature
and high distance-to-spot measurements.
With a straight-forward user interface and soft-key menus,
the Fluke 572-2 makes even complex measurements easy. Quickly navigate and
adjust emissivity, start data logging, or turn on and off alarms, with just a
few pushes of a button.
Features:- Measure
-30 °C to 900 °C (-22 °F to 1652 °F)
- 60:1
distance to spot ratio with dual laser sighting for fast, accurate
targeting
- Multi-language
interface (user select)
- Current
Temperature plus MAX, MIN, DIF, AVG temperature displays
- Compatible
with standard mini-connector K-type thermocouples, including ones you
already own and have installed
- Adjustable
emissivity and predefined emissivity table
- Infrared
and thermocouple temperature on backlit display
- Last
reading Hold (20 seconds)
- High
and low temperature alarm
- Data
storage and review (99 data sets)
- Tripod
mount
- 12 or
24 hour clock
- USB
2.0 computer interface cable
Specifications:
Infrared Measurements | |
Infrared temperature range | -30 °C to 900 °C (-22 °F to 1652 °F) |
IR accuracy (calibration geometry with ambient
temperature 23 °C ± 2 °C) | ≥ 0°C: ± 1°C or ± 1 % of the reading, whichever is greater |
IR repeatability | ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater |
Display resolution | 0.1 °C / 0.1 °F |
Distance: Spot | 60:1 (calculated at 90 % energy) |
Minimum spot size | 19 mm |
Laser sighting | Offset dual laser, output <1 mW |
Spectral response | 8 μm to 14 μm |
Response time (95 %) | <500 ms |
Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
Contact Measurements | |
K-type thermocouple input temperature range | -270 °C to 1372 °C (-454 °F to 2501 °F) |
K-type thermocouple input accuracy (with ambient
temperature 23 °C ± 2 °C) | <-40 °C: ±(1 °C + 0.2 °/1 °C) |
≥-40 °C: ±1 % or 1 °C, whichever is greater | |
<-40 °F: ±(2 °F + 0.2 °/1 °F) | |
≥-40 °F: ±1 % or 2 °F, whichever is greater | |
K-type thermocouple | 0.1 °C/0.1 °F |
K-type thermocouple repeatability | ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater |
Measurement Options | |
Hi/Low alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Switchable celsius and fahrenheit | Yes |
Backlight | Two levels, normal and extra bright for darker environments |
Probe input | K-type thermocouple simultaneous display of probe and IR temperature |
Trigger lock | Yes |
Data storage | 99 points |
Display | Dot matrix 98 x 96 pixels with function menus |
Communication | USB 2.0 |
K-Type Thermocouple Specifications | |
Measurement range (bead probe) | -40 °C to 260 °C (-40 °F to 500 °F) |
Accuracy | ±1.1 °C (±2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F). Typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F) |
Cable length | 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
General Specifications | |
Safety and compliance | IEC 60825-1 |
Operating temperature | 0 °C to 50 °C (32 °F to 122 °F) |
Storage temperature | -20 °C to 60 °C (-4 °F to 140 °F) |
Relative humidity | 10 % to 90 % RH non-condensing up to 30 °C (86 °F) |
Operating altitude | 2000 meters above mean sea level |
Weight | 0.322 kg (0.7099 lb) |
Power | 2 AA batteries |
Battery life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) |