Fluke 375
- Stock: In Stock
- Model: True RMS AC/DC Clamp Meter
Specifications: Fluke 375 True RMS AC/DC Clamp Meter
Electrical Specifications | ||||
AC Current via Jaw | ||||
Range | 374 and 375 | 600.0 A | ||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits (10-100 Hz) | |||
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) | |||
AC Current via Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 374 and 375 | 0.1 A (≤ 600 A) | ||
376 | 0.1 A (≤ 999.9 A) | |||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) | |||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 374 and 375 | 600.0 A | ||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits | |||
AC Voltage | ||||
Range | 374 and 375 | 600.0 V | ||
Resolution | 374 and 375 | 0.1 V | ||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
DC Voltage | ||||
Range | 374 and 375 | 600.0 V | ||
Resolution | 374 and 375 | 0.1 V | ||
Accuracy | 1% ± 5 digits | |||
mV dc | ||||
Range | 375 and 376 | 500.0 mV | ||
Resolution | 0.1 mV | |||
Accuracy | 1% ± 5 digits | |||
Frequency via Jaw | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 10 Hz, ≥10 A | |||
10 – 100 Hz, ≥5 A | ||||
100 – 500 Hz, ≥10 A | ||||
Frequency via Flexible Current Probe | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 20 Hz, ≥ 25 A | |||
20 – 100 Hz, ≥ 20 A | ||||
100 – 500 Hz, ≥ 25 A | ||||
Resistance | ||||
Range | 374 | 6000 Ω | ||
Resolution | 374 | 0.1 Ω (≤ 600 Ω) | ||
375 and 376 | 0.1 Ω (≤ 600 Ω) | |||
Accuracy | 1% ± 5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤ 100 μF) | |||
Accuracy | 1% ± 4 digits | |||
Mechanical Specifications | ||||
Size (L x W x H) | 246 mm x 83 m x 43 mm | |||
Weight | 388 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length | 1.8 m | |||
Environmental Specifications | ||||
Operating Temperature | 10°C – +50°C | |||
Storage Temp | -40°C – +60°C | |||
Operating Humidity | Non condensing (< 10 –°C) | |||
Operating Altitude | 3000 meters | |||
Storage Altitude | 12,000 meters | |||
EMC | EN 61326-1:2006 | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each | |||
Safety Specifications | ||||
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 |