The Fluke 117 digital multimeter is accurate even in low light. Check out the best non-contact multimeter for efficiency in demanding settings today!
Designed by Electricians. Engineered by Fluke – An Investment in Accuracy


With its integrated non-contact voltage detection and the AutoV/LoZ function preventing false readings caused by ghost voltage, the Fluke 117 Electrician's Multimeter is the ideal multimeter for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings, measuring frequency and capacitance. With its easy-to-use design, the Fluke 117 will save you time, allowing you to move from job to job with ease.


Engineered and Tested with Your Safety on the Job in Mind


We test our 117 Multimeters for safe use in CAT III 600 V environments. This is the ideal meter for your electrical work because:

 

The large white LED backlight helps you work in poorly lit areas

VoltAlertTM technology gives you fact, go/no go non-contact voltage detection

AutoVolt and Low Input Impedance modes provide faster, more accurate readings

Features:



VoltAlert™ technology for non-contact voltage detection

AutoVolt automatic AC/DC voltage selection

Low input impedance: helps prevent false readings due to ghost voltage

Large white LED backlight to work in poorly lit areas

True RMS for accurate measurements on non-linear loads

Measures 10 A (20 A overload for 30-seconds)

Resistance, continuity, frequency and capacitance

Min/Max/Average with elapsed time to record signal fluctuations

Compact ergonomic design for one-handed operation

Compatible with optional magnetic hanger (ToolPak™) for hands free operation

CAT III 600 V safety rated

Specifications

Maximum voltage between any terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2

Fuse for A input

11 A, 1000 V FAST Fuse (Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to +50°C

Storage temperature

-40°C to +60°C

Battery type

9 volt Alkaline, NEDA 1604A / IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V

Accuracy

±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution

600.0 V / 0.1 V

Accuracy

2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)

AC millivolts¹ True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts¹ True RMS

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

AC amps True RMS (45 Hz to 500 Hz)

Range/resolution

6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy

1.5% + 3
20 A continuous overload for 30 seconds max

DC amps

Range/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy

1.0% + 3
20 A continuous overload for 30 seconds max

Hz (V or A input)²

Range/resolution

99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz