FLUKE 393FC
FLUKE 393FC
- Stock: In Stock
- Model: Solar Clamp Meter CAT III 1500 V
160,000
Features
- IP54 rated, ideal for work outdoors in dusty or damp conditions on solar arrays and wind power systems
- DC power measurement, showing readings in kVA
- Audio polarity indicator helps prevent accidental miswires
- Visual continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
- Logging and reporting of test results via software
- Measure safely with CAT III 1500 V rated clamp meter
- Thin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cables
- MC4 test lead sets are designed for use with solar clamp meters that accept 0.15" (4 mm) banana plugs, rated to CAT III 1000 V / CAT IV 600 V
- View voltage and current simultaneously with the meter's dual display
Applications
- Solar arrays
- Wind power
- Electric railways
- Data centers
- Battery Banks for uninterruptible power supplies
Fluke 393FC Specifications
Maximum Voltage Between Any Terminal and Earth Ground | 1000 V AC 1500 V DC |
Electrical Specifications | Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C) |
AC Current: Jaw | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz) Crest factor (50/60 Hz): 2.5 at 600 A 3 at 500 A 1.42 at 999.9 A Add 2% for C.F. >2 |
AC Current: Flexible Current Probe | Range: 999.9 A; 2500 A Resolution: 0.1 A (≤999.9 A); 1 A (≤2500 A) Accuracy: 3 % RD + 5 digits (10 to 500 Hz) Crest factor (50/60Hz): 2.5 at 1400 A 3 at 1100 A 1.42 at 2500 A Add 2% for C.F. >2 |
Position Sensitivity | Distance from optimum: A B C i2500-18 Flex: 1.4" (35.6 mm) 2" (50.8 mm) 2.5" (63.5 mm) Error: ±0.5% ±1% ±2% |
DC Current | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsets |
AC Voltage | Range: 600 V; 1000 V Resolution: 0.1 V (≤600 V); 1 V (≤1000 V) Accuracy: 1% RD + 5 digits (20 to 500 Hz) |
DC Voltage | Range: 600 V; 1500 Resolution: 0.1 V (≤600 V), 1 V (≤1500 V) Accuracy: 1% RD + 5 digits |
mV DC | Range: 500 mV Resolution: 0.1 mV Accuracy: 1% RD + 5 digits |
Amps Frequency: Jaw | Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 to 10 Hz ≥10 A 10 to 100 Hz, ≥5 A 100 to 500 Hz, ≥10 A |
Amps Frequency: Flexible Current Probe | Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 to 10 Hz ≥10 A 10 to 100 Hz, ≥5 A 100 to 500 Hz, ≥10 A |
Voltage Frequency | Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 to 20 Hz, ≥5 V 20 to 100 Hz, ≥5 V 100 to 500 Hz, ≥10 V |
DC Power | Range: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range) Resolution: 0.1 kVA, 1 kVA Accuracy: 2% RD + 2 kVA, 2% RD + 20 kVA |
Resistance | Range: 600 Ω, 6000 Ω, 60 kΩ Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ) Accuracy: 1% RD + 5 digits |
Capacitance | Range: 100 μF, 1000 μF Resolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF) Accuracy: 1% RD + 5 digits Inrush trigger level: 5 A |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -40 to 140°F (-40 to 60°C) |