Main Menu / Categories
Your Cart

Fluke 376FC

Fluke 376FC
  • Stock: In Stock
  • Model: True-rms AC/DC Clamp Meter with iFlex 1000A
115,000
+ 500 Shipping charges

The Fluke 376 FC is part of the Fluke Connect family of wireless test tools.  Now you can:

  • Log and trend measurements to pinpoint intermittent faults
  • Transmit results wirelessly via Fluke Connect® Measurements app
  • Create and send reports right from the field
  • Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices
The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.
  • Connect your meter to your smartphone with Fluke Connect Measurements
  • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
  • Record results directly to your phone and the Cloud
  • Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
  • Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
  • iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
  • TPAK magnetic hanging strap (included)
  • Integrated VFD low pass filter for accurate motor drive measurements
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • CAT IV 600 V, CAT III 1000 V safety rating
  • Three-year warranty
  • Soft carrying case
Measurement Capability
  • 1000 A ac and dc current measurement
  • 2500 A ac current measurement with iFlex flexible current probe
  • 1000 V ac and dc voltage measurement
  • True-rms voltage and current for accurate measurements on non-linear signals
  • Frequency measurement to 500 Hz with body jaw and iFlex
  • Resistance measurement to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV dc measurement range to interface with other accessories
  • 1000 μF capacitance measurement
  • General Specifications
    AC Current via Jaw
    Range999.9 A
    Resolution 0.1 A
    Accuracy 2% ±5 digits (10 Hz to 100 Hz)
    2.5% ±5 digits (100-500 Hz)
    Crest Factor (50 Hz/60 Hz)3 @ 500 A
    2.5 @ 600 A
    Add 2% for C.F. >2
    AC Current via Flexible Current Probe
    Range2500 A
    Resolution0.1 A (≤ 600 A)
    1 A (≤ 2500 A)
    Accuracy3% ±5 digits (5 – 500 Hz)
    Crest Factor (50/60Hz)3.0 at 1100 A
    2.5 at 1400 A
    1.42 at 2500 A
    Add 2% for C.F. > 2
    Position Sensitivity
    Flexible current probe
     i2500-10 Flexi2500-18 Flex
    A  
    Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)
    Error±0.5 %±0.5 %
    B  
    Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)
    Error±1.0 %±1.0 %
    C  
    Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)
    Error±2.0 %±2.0 %
    Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    DC Current
    Range600.0 A
    Resolution0.1 A
    Accuracy2% ±5 digits
    AC Voltage
    Range1000 V
    Resolution0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy1.5% ±5 digits (20 Hz to 500 Hz)
    DC Voltage
    Range1000 V
    Resolution0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy1% ±5 digits
    mV dc
    Range500.0 mV
    Resolution0.1 mV
    Accuracy1% ±5 digits
    Frequency via Jaw
    Range5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5% ±5 digits
    Trigger level 5 Hz to 10 Hz, ≥10 A
    10 Hz to 100 Hz, ≥5 A
    100 Hz to 500 Hz, ≥10 A
    Frequency via Flexible Current Probe
    Range5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5% ±5 digits
    Trigger level 5 Hz to 20 Hz, ≥25 A
    20 Hz to 100 Hz, ≥20 A
    100 Hz to 500 Hz, ≥25 A
    Resistance
    Range60 kΩ
    Resolution0.1 Ω (≤600 Ω)
    1 Ω (≤6000 Ω)
    10 Ω (≤60 kΩ)
    Accuracy1% ±5 digits
    Capacitance
    Range1000 μF
    Resolution0.1 μF (≤ 100 μF)
    1 μ F (≤ 1000 μF)
    Accuracy1% ±4 digits
    Mechanical Specifications
    Maximum voltage between any terminal and earth ground1000 V
    Batteries2 AA, NEDA 15A, IEC LR6
    Operating temperature-10 °C to +50 °C
    Storage temperature-40 °C to +60 °C
    Operating humidity -
    non-condensing (< 10°C)
    ≤90% RH (at 10 °C to 30 °C)
    ≤75% RH (at 30 °C to 40 °C)
    ≤45% RH (at 40 °C to 50 °C)