DSO5072P HANTEK
Pre-Order
Tags:
dso5072p
, hantek
, pre
, orders digital
, storage
, oscilloscope
, 70mhz oscilloscopes desktop
DSO5072P HANTEK
- Stock: Pre-Order
- Model: Digital Storage Oscilloscope 70MHz
55,000
Model | DSO5202P | DSO5102P | DSO5072P |
Acquisition | |||
Sample Rate | Real-Time Sample: 1GS/s Equivalent Sample: 25GS/s | ||
Acquisition Modes | |||
Normal | Normal data only | ||
Peak Detect | High-frequency and randon glith capture | ||
Average | Wavefom Average, selectable 4,8,16,32,64,128 | ||
Inputs | |||
Inputs Coupling | AC, DC, GND | ||
Inpits Impendance | 1MΩ±2% ‖20pF±3pF | ||
Probe Attenuation | 1X, 10X | ||
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | ||
Maximum Input Voltage | CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. | ||
Horizontal | |||
Sample Rate Range | 500MS/s--1GS/s | ||
Waveform Interpolation | (sin x)/x | ||
Record Length | 40K | ||
SEC/DIV Range | 2ns/div to 80s/div | ||
Sample Rate and Delay Time Accuracy | ±50ppm(at over any ≥1ms time interval) | ||
Offset Range | 2ns/div to 8ns/div; (-8div x s/div) to 20ms; | 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 80s/div; (-8div x s/div) to 400s | |
Delta Time Measurement Accuracy (Full Bandwidth) | Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 | ||
Vertical | |||
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously | ||
Position Range | 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div to 10V/div, ±50V | ||
Bandwidth | 200MHz | 100MHz | 70MHz |
Rise Time at BNC( typical) | 1.8ns | 3.5ns | 5ns |
Math | +, -, *, /, FFT | ||
FFT | Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point | ||
Bandwidth Limit | 20MHz | ||
Low Frequency Response (-3db) | ≤10Hz at BNC | ||
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div | ||
DC Measurement Accuracy, Average Acquisition Mode | When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div | ||
Volts Measurement Repeatability, Average Acquisition Mode | Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
Measure | |||
Cursor Measurement | Voltage difference between cursors: △V Time difference between cursors: △T Reciprocal of △T in Hertz (1/ΔT) | ||
Auto Measuerment | Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF | ||
Display | |||
Display Type | 7 inch 64K color TFT (diagonal liquid crystal) | ||
Display Resolution | 800 horizontal by 480 vertical pixels | ||
Display Contrast | Adjustable (16 gears) with the progress bar | ||
Probe Compensator Output | |||
Output Voltage( typical) | About 5Vpp into ≥1MΩ load | ||
Frequency(typical) | 1kHz | ||
Power Supply | |||
Supply Voltage | 100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ 120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ | ||
Power Consumption | <30W | ||
Fuse | 2A, T rating, 250V | ||
Environmental | |||
Temperature | Operating: 32℉ to 122℉ (0℃ to 50℃); Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃) | ||
Cooling Method | Convection | ||
Humidity | +104℉ or below (+40℃ or below): ≤90% relative humidity; 106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity | ||
Altitude | Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet) |