FLUKE 1625-2 KIT
Pre-Order
FLUKE 1625-2 KIT
- Stock: Pre-Order
- Model: GEO Earth Ground Tester Kit
Product overview: Fluke 1625-2 GEO Earth Ground Tester Kit
The Most Complete Stakeless Earth Ground Tester
The Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments. Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.
Stakeless earth ground measurement testing
- You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil
- The Fluke 1625-2 earth ground tester can measure earth ground loop resistances using only clamps
- With this test method, two clamps are placed around the earth ground rod and each are connected to the tester
The Fluke 1625-2 improves your earth ground testing process with:
- Automatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value
- R* measurement - calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see
- Adjustable limits - for quicker testing
The Fluke 1625-2 gives you versatility in earth ground testing
- 3- and 4-pole fall-of-potential, earth resistance loop testing
- 4-pole soil resistivity testing
- Selective earth ground rod testing using 1 clamp
- Stakeless earth ground rod testing using 2 clamps
The Fluke 1625-2 offers you simpler, faster earth ground tests than ever before
- The 1625-2 offers internal memory storage up to 1500 records
- Accessible via USB port for rapid data transfer and viewing of results
- This earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing
Additional tool features
- Heavy duty stakes can be hammered into dry, hard soil.
- And new color-coded wires make setup simple and help eliminate mistakes and speed up setup and tear down time as much as 50%
- IP56 rated for outdoor use
- Rugged carrying case
Specifications: Fluke 1625-2 GEO Earth Ground Tester Kit
General Specifications Memory Internal memory storage up to 1500 records accessible via USB port Measuring function Interference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC Display 4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility Operation Central rotary switch and function keys Temperature Range Operating temperature -10°C to 50°C (14°F to 122°F) Storage temperature -30°C to 60°C (-22°F to 140°F) Temperature coefficient ±0.1% of reading/°C < 18°C > 28°C Type of protection IP56 for case, IP40 for battery door according to EN60529 Max voltage Warning – socket "clamp" to socket E, ES, S or H Urms = 0 V Sockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse) Safety Protection by double and/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2 Quality standard Developed, designed and manufactured to comply with DIN ISO 9001 External field influence Complies with DIN 43780 (8/76) Auxiliary power 6 x 1.5 V alkaline (IEC LR6 or type AA) Battery life span With IEC LR6/type AA: typ. 3,000 measurements (RE+RH ≤ 1 kΩ) With IEC LR6/type AA: typ. 6,000 measurements (RE + RH > 10 kΩ) Dimensions (W x H x D) 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in) Weight ≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case Case material Polyester Measurement of Interference Voltage DC + AC (UST) Measuring limits of error: method Full wave rectification Measuring range 1 V to 50 V Display range 0.0 V to 50 V Resolution 0.1 V Frequency range DC/AC 45 Hz to 400 Hz sine Accuracy ±(5% of rdg + 5 digit) Measuring sequence Approx. 4 measurements/s Internal resistance Approx. 1.5 MΩ Max. overload Urms = 250 V Measurement of Interference Frequency (F) Measuring limits of error: method Measurement of oscillation period of the interference voltage Measuring range 6.0 Hz to 400 Hz Display range 16.0 Hz to 299.9 Hz to 999 Hz Resolution 0.1 Hz to 1 Hz Range 1 V to 50 V Accuracy ±(1% of rdg + 2 digit) Earthing Resistance (RE) Measuring method Current and voltage measurement with probe as IEC61557-5 Open circuit voltage 20/48 V, AC Short circuit current 250 mA AC Measuring frequency 94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R1 Noise rejection 120 dB (16 2/3 , 50 , 60, 400 Hz) Max. overload Urms = 250 V