Product overview: Fluke 820-2 LED Stroboscope

Investigate and observe potential mechanism failure with confidence

Identifying the running speed of rotating equipment can be difficult, but the Fluke 820-2 LED Stroboscope simplifies the process allowing you to perform stop motion diagnostics without actually stopping, or making contact, with the machine you are working on. Whether you are trying to diagnose parasitic oscillations, slippage, or unwanted distortions, the 820-2 LED Stroboscope is the ideal frontline troubleshooting, process or product research and development tool.

Other useful features:

  • Includes digital pulse width modulation for exceptionally sharp images at high speeds
  • Provides rugged, durable design that uses solid-state LEDs with no filaments, gases, hollow cavities, or glass; (1 meter drop tested)
  • Features quartz-accuracy control system for high accuracy–0.02% (+/- 1 digit)
  • Provides a multi-line LCD display
  • Includes advance or retard flash timing for viewing gear teeth, cutting surfaces, repeats, or drifting equipment
  • Features simple push button operation with 2x and ÷2 buttons for easy adjustment

    Specifications: Fluke 820-2 LED Stroboscope

    Mechanical Specifications
    Size (HxWxL)5.71 cm x 6.09 cm x 19.05 cm
    2.25 in x 2.4 in x 7.5 in
    Weight0.24 kg
    Environmental Specifications
    Operating temperature0 °C to +45 °C
    Storage temperature-10 °C to +50 °C
    Operating humidity (without ondensation)Non-condensing (<10 °C)
    90 % RH (10 °C to 30 °C)
    75 % RH (30 °C to 40 °C)
    45 % RH (40 °C to 50 °C)
    Absorption/corrosion30 °C, 95 % RH, 5 day
    Product functions normally
    Operating altitude2,000 m
    Storage altitude12,000 m
    VibrationMIL-PRF-28800F Class 2
    Impact resistance1 m drop
    EMI, RFI, EMCEN61326-1:2006
    Safety Compliance
    Agency approvalsCE
    Class III (SELV) Pollution Degree 2
    Miscellaneous Specifications
    Flash Frequency
    Range30 to 300,000 FPM
    0.5 to 5000 Hz
    Accuracy0.02 %
    Resolution30 to 999 FPM = 0.1
    1000 to 300,000 = 1
    0.5 Hz to 999 Hz = 0.1
    1000 Hz to 5000 Hz = 1
    Frequency settingFPM or Hz
    Flash Pulse
    DurationAdjustable in μs or degrees
    DelayAdjustable in μs or degrees
    Light
    ColorApproximately 6500 K
    Emission output4,800 lx @ 6000 FPM at 30 cm
    External Trigger
    MethodConnector to externally control trigger
    High level3 V to 32 V
    Low level<1 V
    Minimum pulse width50 μs connection