Fluke 1503 Insulation Resistance Meter Price In Pakistan
- Stock: In Stock
- Model: Insulation Resistance Meter
Key features
- A rugged, compact insulation resistance tester for residential and commercial electricians
- Performs insulation tests from 0.01 MΩ to 2000 MΩ
- Offers two insulation test voltages: 500 V and 1000 V
- Includes live circuit detection to prevent insulation test if voltage >30 V is detected
- Measures resistance from 0.01 Ω to 20.00 kΩ
Other useful capabilities:
- Measures AC/DC voltage from 0.1 V to 600 V
- Includes auto-discharge of capacitive voltage for added user protection
- Provides lo-ohms earth-bond continuity (200 mA)
- Simplifies repetitive or hard-to-reach testing with the remote test probe
- Saves battery power with auto power off
- Presents results on a large, backlit display
- Features CAT IV 600 V overvoltage category rating
- Comes with remote probe, test leads, test probes, alligator clips, and one-year warranty
- Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
- Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
Specifications: Fluke 1503 Insulation Resistance Meter
AC/DC Voltage Measurement | |||
Accuracy | Range | 600.0 V | |
Resolution | 0.1 V | ||
50 Hz to 400 Hz ±(% of Rdg + Digits) | ±(2% + 3) | ||
Input impedance | 3 MΩ (nominal), < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalanced) | > 60 dB at DC, 50 or 60 Hz | ||
Overload protection | 600 V rms or DC | ||
Earth Bond Resistance Measurement | |||
Range/Resolution | 20.00 Ω | 0.01 Ω | |
200.0 Ω | 0.1 Ω | ||
2000 Ω | 1.0 Ω | ||
20.00 kΩ | 0.01 kΩ | ||
Accuracy | ±(1.5% + 3) | ||
Overload protection | 2 V rms or DC | ||
Open circuit test voltage | > 4.0 V, < 8 V | ||
Short circuit current | > 200.0 mA | ||
Insulation Specifications | |||
Measurement range | 0.01 MΩ to 2000 MΩ | ||
Test voltage | 500 V, 1000 V | ||
Test voltage accuracy | + 20%, - 0% | ||
Short circuit current | 1 mA nominal | ||
Auto discharge | Discharge time < 0.5 second for C = 1 µF or less | ||
Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test | ||
Maximum capacitive load | Operable with up to 1 µF load | ||
Measure accuracy | |||
500 V | ±(1.5% + 5) | ||
1000 V | ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ | ||
General Specifications | |||
Maximum voltage applied to any terminal: | 600 V AC rms or DC | ||
Storage temperature | -40°C to 60°C (-40°F to 140°F) | ||
Operating temperature | -20°C to 55°C (-4°F to 131°F) | ||
Temperature coefficient | 0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F) | ||
Relative humidity | |||
0% to 95% @ 10°C to 30°C (50°F to 86°F) | |||
0% to 75% @ 30°C to 40°C (86°F to 104°F) | |||
0% to 40% @ 40°C to 55°C (104°F to 131°F) | |||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | ||
Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) | ||
Electromagnetic compatibility | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) | ||
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) | ||
Certifications | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition | ||
Batteries | Four AA batteries (NEDA 15A or IEC LR6) | ||
Battery llife | Insulation test use: | Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. | |
Resistance measurements: | Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. | ||
Size (H x W x L) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) | ||
Weight | 550 g (1.2 lb) | ||
IP rating | IP40 | ||
Altitude | Operating | 2000 m CAT IV 600 V, 3000 m CAT III 600 V | |
Non-operating (storage) | 12,000 m | ||
Over-range | |||