FLUKE 377FC
- Stock: In Stock
- Model: Non-Contact Voltage True-rms AC/DC
DESCRIPTION:
Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex
Key Features:
Measure voltage and current with your clamp jaw
Faster, safer testing - all without touching a live wire -
using FieldSense™ technology
Complete 3-phase voltage and current tests in 3 quick steps
Specifications: Fluke 377 FC Non-Contact Voltage True-rms
AC/DC Clamp Meter with iFlex
General specifications: | ||
General Maximum Voltage between any Terminal and Earth
Ground | 1000 V | |
Battery | Type | 2 AA IEC LR6 alkaline |
Life | 200 hour | |
Display | Dual readout | |
Automatic Power Off | 20 minutes | |
Electrical: | ||||
AC Current: Jaw | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2 % ±5 digits (45 Hz to 66 Hz) | |||
Crest Factor (50/60 Hz) | 3 @ 500 A | |||
AC Current: Flexible Current Probe: | ||||
Range | 2500 A | |||
Resolution | 1 A (≤2500 A) 0.1 A (≤999.9 A) | |||
Accuracy | 3 % ±5 digits (5 Hz to 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A | |||
Position Sensitivity: | ||||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5 % | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0 % | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0 % | |
Measurement uncertainty assumes centralized primary
conductor at optimum position, no external electrical or magnetic field, and
within operating temperature range. | ||||
DC Current: | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2 % ±5 digits1 | |||
[1]When using the ZERO function to compensate for offsets | ||||
AC Voltage: Field Sense: | ||||
Range | 1000 V | |||
Resolution | 1 V (≤1000V) | |||
Accuracy | ≤4/0 AWG | 3 % ±5 digits (45 Hz to 66 Hz) | ||
≥4/0 AWG | 5 % ±5 digits (45 Hz to 66 Hz) | |||
Position wire as close as possible to jaw opening (see
illustration). | ||||
AC Voltage: Test Leads: | ||||
Range | 600.0 V 1000 V | |||
Resolution | 0.1 V (≤600.0 V) | |||
Accuracy | 1 % ±5 digits (20 Hz to 500 Hz) | |||
DC Voltage: | ||||
Range | 600.0 V | |||
Resolution | 0.1 V (≤600.0 V) | |||
Accuracy | 1 % ±10 digits | |||
mV dc: | ||||
Range | 500.0 mV | |||
Resolution | 0.1 mV | |||
Accuracy | 1 % ±5 digits | |||
Amps Frequency: Jaw: | ||||
Range | 45 Hz to 66 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5 % ±5 digits | |||
Trigger Level | 5 Hz to 10 Hz, ≥10 A | |||
Amps Frequency: Flexible Current Probe | ||||
Range | 5.0 Hz to 500.0 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5 % ±5 digits | |||
Trigger Level | 5 Hz to 20 Hz, ≥25 A | |||
Resistance: | ||||
Range | 60.00 kΩ | |||
Resolution | 0.1 Ω (≤600.0 Ω) | |||
Accuracy | 1 % ±5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤100.0 μF) | |||
Accuracy | 1 % ±4 digits | |||
Mechanical | ||||
Size (L x W x H) | 274 mm x 86 mm x 47 mm | |||
Weight (with Batteries) | 463 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length (head to electronics
connector) | 1.8 m | |||
Rogowski Coil Length | 450 mm | |||
Environmental: | ||||
Operating Temperature | -10 °C to 50 °C | |||
Storage Temperature | -40 °C to 60 °C | |||
Operating Humidity (without condensation) | Non condensing (<10 °C) | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C >28 °C
or <18 °C | |||
Ingress Protection | IEC 60529: IP30 (jaw closed) | |||
Operating Altitude | 2000 m | |||
Storage Altitude | 12 000 m | |||
Electromagnetic Compatibility (EMC) | ||||
International | IEC 61326-1: Portable Electromagnetic Environment | |||
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is necessary for the
internal function of the equipment itself. | ||||
Class B: Equipment is suitable for use in domestic
establishments and in establishments directly connected to a low voltage
power supply network which supplies buildings used for domestic purposes. | ||||
Korea (KCC) | Class A equipment (Industrial Broadcast &
Communications Equipment) | |||
Class A: Equipment meets requirements for industrial
electromagnetic wave equipment and the seller or user should take notice of
it. This equipment is intended for use in business environments and not to be
used in homes. | ||||
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt
device per clause 15.103. | |||
Safety: | ||||
General | IEC 61010-1: Pollution degree 2 | |||
Measurement | IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | |||
Current Clamp for Leakage Current Measurements | IEC 61557-13: Class 2, ≤30 A/m | |||