FLUKE 177C
- Stock: In Stock
- Model: True-RMS Digital Multimeter
Specification:
Fluke 177 True-RMS Digital Multimeter with display backlight
Key Features:
The Fluke 177 True-RMS digital multimeter measures twice as
fast as other multimeters; digital display with analog bar graph and backlight.
Safety rated CAT III 1000 V, CAT IV 600 V
Measures AC and DC voltage to 1000 V
True-RMS AC current and voltage plus frequency, capacitance,
resistance, continuity and diode measurements
Specifications: Fluke 177 True-RMS Digital Multimeter with
display backlight
Specifications: | ||
Voltage DC | Accuracy1 | ±(0.09% + 2) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Voltage AC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Current DC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Current AC | Accuracy1 | ±(1.5% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Resistance | Accuracy1 | ±(0.9% + 1) |
Max. resolution | 0.1 Ω | |
Maximum | 50 MΩ | |
Capacitance | Accuracy1 | ±(1.2% + 2) |
Max. resolution | 1 nF | |
Maximum | 10,000 µF | |
Frequency | Accuracy1 | ±(0.1% + 1) |
Max. resolution | 0.01 Hz | |
Maximum | 100 kHz | |
1. Accuracies are best accuracies for each function | ||
Environmental Specifications: | ||
Operating temperature | -10°C to +50°C | |
Storage temperature | -30°C to +60°C | |
Humidity (without condensation) | 0% – 90% (0°C – 35°C) | |
Safety Specifications: | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III | |
Agency approvals | UL, CSA, TÜV listed and VDE Pending | |