Tzone TEMPU02 60DAYS
- Stock: In Stock
- Model: TZONE 60 Days Single Use Temperature PDF Data Logger
Description:
Single-use PDF Temperature Data Logger
Small, light, waterproof and in a food safe wrapper, the single-use data logger
is ideal for monitoring the temperature of shipments in transit. Recordings are
started by pressing the start button. The data logger is then placed inside the
carton and dispatched. At the receiving end, the data logger is taken from the
package and removed from the protective wrapper. It is placed into the USB slot
on a computer to get a PDF report directly without any software and
driver.
This data logger is used mainly to monitor and verify temperature-sensitive
goods, equipment or areas. Example: Cold Chain, Refrigeration, transportations
and food & pharmaceutical.
·
Encrypted PDF Report: Automatically generating
encrypted PDF report, no software required.
·
EN12830 Compliant: Complies to EN12830:1999
for transport, storage and distribution of chilled, frozen, deep-frozen,
quick-frozen food and others.
·
IP67 Protection Class: Food-safety and
water-proof packing comply to IP67 protection class.
Specifications:
Recording Option: Single-use
Temperature measuring range: -20°C~+60°C
Resolution: 0.1°C
Accuracy: ±0.5°C(-20℃~+40℃); others, ±1℃
Data Storage Capacity: 10,000 readings
Recording Interval: 10 minutes (standard, others on request)
Recording Duration: 60 days
Temperature Alarm: >8°C or <2°C
Alarm Delay: 0 mins
Alarm Type: The red LED will flash every 10s if the temperature has been out of
range
Start Delay: 30 mins
Report generation Automatic PDF report
Sensor: Internal NTC thermal resistor
Communication interface: USB 2.0 interface
Power supply: CR2032 button cell
Battery life: In normal temperature, 2 years
Waterproof level: IP67 (with Seal-Bag)
Operating Instructions:
1.
DO NOT tear or cut off the plastic bag when in use.
1.
Press and hold the button for more than 3 sec. then
the “OK” light will brighten in 3 sec., which indicates a successful starting,
then you can put the data logger in the place where you want to monitor and
record.
1.
When logging, if you don’t press the button, the
indicated lights won’t flash. If you want to know the status of the Logger, you
should press the button shortly, then the “OK” light(normal temperature) or the
“ALARM” light(over temperature) will flash.
1.
If the memory full or press and hold the button for
more than 3 sec. the “ALARM” light will brighten in 3 sec., which indicates a
successful stopping.
1.
Tear or cut off the plastic bag and insert the
logger into an available USB port on a PC. “OK” light and “ALARM” light will
flash in turn when a PDF report is generating. When PDF report has generated,
the“OK” light will bright until pull out from the USB port.