DSO 4072C HANTEK

DSO 4072C HANTEK
  • Stock: Pre-Order
  • Model: Digital Storage Oscilloscope 70MHZ
65,000
No Shipping Charges
ModelDSO4202CDSO4102CDSO4072C
Oscilloscope


Sample RateSampling Rate Range: 1GSa/s
Equivalent Sample Rate: 25GSa/s
Acquisition Modes
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWavefom Average, selectable 4,8,16,32,64,128
Inputs


Inputs CouplingAC, DC, GND
Inpits Impendance1MΩ±2% ‖20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Maximum Input VoltageCAT I and CAT II: 300VRMS (10×)
CAT III: 150VRMS(1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal


Sample Rate Range1GS/s
Waveform Interpolation(sin x)/x
Record Length40K
SEC/DIV Range2ns/div to 40s/div
Sample Rate and±50ppm(at over any ≥1ms time interval)
Delay Time Accuracy
Position Range

2ns/div to 8ns/div;

(-8div x s/div) to 20ms;

20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Position Range2mV/div to 10V/div
Bandwidth200MHz100MHz70MHz
Rise Time at BNC( typical)1.8ns 3.5ns5ns
Offset Range

2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±1V

500mV/div to 2V/div, ±40V; 5V/div to 10V/div, ±50V

Math+, -, *, /, FFT
FFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
When vertical displacement is zero, and N 16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N
16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div