Overview:


The Fluke 1587 FC Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
The Fluke 1587 FC Insulation Multimeter adds four powerful new diagnostic functions through the Fluke Connect® Measurements app:
  • PI/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
  • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets
Product highlights
  • PI/DAR timed ratio tests
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • VFD low-pass filter for accurate motor drive measurements
  • Auto-discharge of capacitive voltage for added user protection
  • Insulation test (1587 FC: 0.01 MΩ to 2 GΩ)
  • Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V) for many applications
  • AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Large display with backlight
  • Rugged, utility hard case allows you to bring everything you need for the job
  • Included accessories: Remote probe, test leads and probes, alligator clips, K-type thermocouple
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient hands free operation
Features:


  • PI/DAR measurements with TrendIt  graphs
  • Memory storage through Fluke Connect Measurements app
  • Temperature Compensation through Fluke Connect Measurements app
  • VFD low-pass filter for accurate motor drive measurements
  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test: 0.01 MΩ to 2.0 GΩ
  • Auto-discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency
  • Capacitance
  • Diode test
  • Temperature
  • Min/Max
  • AC/DC Voltage
  • DC Millivolts
  • AC/DC Milliamps
  • Resistance (0.1 Ω to 50 MΩ)
  • Continuity
  • Remote probe, test leads, alligator clips
  • K-type thermocouple
  • Rugged, utility hard case
  • Auto power off
 
Specifications:


Electrical Specifications

AC voltage measurement

Range

600.0 mV

Resolution

0.1 mV

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)

6.000 V

Resolution

0.001 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)

60.00 V

Resolution

0.01 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)

600.0 V

Resolution

0.1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)¹

1000 V

Resolution

1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(2% + 3)

Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

±(2% + 3)¹

¹ 1 kHz bandwidth

Low-Pass Filter Voltage 

Range

600.0 mV

Resolution

0.1 mV

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

6.000 V

Resolution

0.001 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

60.00 V

Resolution

0.01 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

600.0 V

Resolution

0.1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(1% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

1000 V

Resolution

1 V

Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

±(2% + 3)

Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

+(2% + 3), -(6% - 3)

DC Voltage Measurement

Range

Resolution

Accuracy ±(% of Rdg + Counts)

6.000 V dc

0.001 V

±(0.09% + 2)

60.00 V dc

0.01 V

±(0.09% + 2)

600.0 V dc

0.1 V

±(0.09% + 2)

1000 V dc

1 V

±(0.09% + 2)

Input impedance 

10 MΩ (nominal), <100 pF

Normal mode rejection ratio 

>60 dB @ 50 Hz or 60 Hz

Common mode rejection ratio 

>120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)

Accuracies apply to ± 100% of range

DC Millivolts Measurement

Range

Resolution

Accuracy ±(% of Rdg + Counts)

600.0 mVdc

0.1 mV

±(0.1% + 1)

DC and AC Current Measurement

AC 45 Hz to 1000 Hz

Range

400 mA

Resolution

0.1 mA

Accuracy ±(% of Rdg+Counts)

±(1.5% + 2)¹

Burden voltage (Typical)

2 mV/mA

Range

60 mA 

Resolution

0.01 mA 

Accuracy ±(% of Rdg+Counts)

±(1.5% + 2)¹

Burden voltage (Typical)

2 mV/mA

DC

Range

400 mA

Resolution

0.1 mA

Accuracy ±(% of Rdg+Counts)

±(0.2% + 2)

Burden voltage (Typical)

2 mV/mA

Range

60 mA

Resolution

0.01 mA

Accuracy ±(% of Rdg+Counts)

±(0.2% + 2)

Burden voltage (Typical)

2 mV/mA

Overload

600 mA for 2 minutes maximum

Fuse protection for mA input

0.44 mA, 1000 V, IR 10 kA

AC conversion

Inputs are ac-coupled and calibrated to the rms value of sine wave input

Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.

¹ 1 kHz bandwidth

Ohms Measurement

Range

Resolution

Accuracy +(% of Rdg+Counts)¹

600.0 Ω

0.1 Ω