FLUKE 1775
Pre-Order
FLUKE 1775
  • Stock: Pre-Order
  • Model: Three-Phase Power Quality Analyzers
3,050,000
No Shipping Charges

Key features

Voltage inputs
Number of inputs4 inputs, 3 phases and neutral referenced to PE (5 connectors)
Measurement category1000 V CAT III / 600 V CAT IV
Maximum input voltage1000 V rms / 1000 V dc (1700 Vpk)
Nominal voltage rangeWye and single phase: variable (50 V – 1000 V)
Delta: Variable (100 V – 1000 V)
IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V
Input impedance10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE
BandwidthDC to 30 kHz for PQ measurements, excluding transients
Resolution24-bit synchronous sampling
Sampling frequency80 kS/s at 50/60 Hz
Scaling1:1, variable for use of potential transformers
Voltage transients
Measurement range±8 kV
Sampling rate1775: 1 MS/s
1777: 1 MS/s, 20 MS/s
BandwidthDC to 1 MHz
TriggerAdjustable trigger level. Triggers on high-frequency components > 1.5 kHz
Resolution14-bit synchronous sampling
Current inputs
Number of inputs4 inputs 3 phases and Neutral, range selected automatically to attached sensor
RangeAC1 A to 1500 A with i17XX-FLEX1500 12
1 A to 1500 A with i17XX-FLEX1500 24
3 A to 3000 A with i17XX-FLEX3000 24
6 A to 6000 A with i17XX-FLEX6000 36
40 mA to 40 A with clamp i40s-EL
4 A to 400 A with clamp i400s-EL
DC20 A to 2000 A with 80i-2010-EL clamp
BandwidthDC to 30 kHz
Resolution24-bit synchronous sampling
Sampling frequency80 kS/s at 50/60 Hz
Scaling1:1, variable
Input voltageClamp: 50 mV / 500 mV rms; CF 2.8
Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4
all at nominal probe range
Input impedance11 kΩ
Data acquisition voltage and current
Input mains frequencyDC, 50/60 Hz  15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz)
Topologies1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta
Data storageFluke 1773/1775: 8 GB internal (expandable with microSD card)
Fluke 1777: 32 GB microSD card (installed)
Memory sizeTypical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.
The number of possible logging sessions and logging period depends on user requirements
Real time accuracyInternal: 3 ppm (0.26 s per day, 8 s per month)
NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTC
GPS: < 1 ms absolute to UTC
Trend interval
Measured parameterSee operator manual
Trend intervalUser selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging interval min/max valuesVoltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)
Aux, Power: 200 ms
Total harmonic distortionTHD for voltage and current is calculated on 50 harmonics
Power quality measurements
Measured parameterSee operator manual
Harmonicsh0 … h50
% fund and RMS for voltage, current and power
Phase angles for voltage and current up to h11
Interharmonicsih0… ih50
% fund and RMS for voltage and current
Supraharmonics2–9 kHz with 200 Hz bins
9–30 khz with 2 kHz bins
RMS for voltage and current
Harmonics measurement methodGrouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.
Method selected automatically based on configured PQ standard or user configurable.
Total harmonic distortionCalculated on up to 50 harmonics (depends on selected PQ standard)
Mains signaling2 frequencies in the range from 110 Hz to 3000 Hz
EventsVoltageDip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients
CurrentInrush current
Triggered recordingsHalf cycle RMS of voltage and current for 10 s
Waveform of voltage and current for 10/12 cycles
Mains signaling: 200 ms RMS of mains signaling voltage up to 120 s
Transients: Waveform of voltage
(Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts)
Standard compliance
PowerIEEE 1459
HarmonicsIEC 61000-4-7: Class 1
IEEE 519 (short time and very short time harmonics)
FlickerIEC 61000-4-15 Class F1
Power qualityIEC 61000-4-30 Class A, IEC 62586 PQI-A-PI
Power quality complianceEN 50160 + GOST + NEQUAL + NETCODE + FOL
Interfaces
Ethernet1 Gbit/s 1000BASE-T
USB type AUSB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA
USB-CUSB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)
Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)
USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA
WiFi/BLE module1802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode
Bluetooth 5.0/BLE
Antenna: Internal and external2
LTE/4G module3LTE-A Cat 12
Worldwide LTE-A and UMTS/HSPA+ coverage
Antenna: External2
GPSMCX connector to attach a GNSS antenna for GPS/GLONASS2
1 Not in 177X/BASIC versions
2 Requires 5m extension cable, Fluke p/n 5263915
3 Availability and supported providers vary by country. Check with your local Fluke representative.