Main Menu / Categories
Your Cart

FLUKE 18B+

FLUKE 18B+
Hot
Tags: FLUKE 18B+
FLUKE 18B+
  • Stock: In Stock
  • Model: Digital Multimeter
35,500
+ 350 Shipping charges

Description

MULTIMETER 18B+ FLUKE In Pakistan

Use 18B+ multimeter to check and test most electronic products. The instrument is easy to use and is significantly improved compared with the original Fluke 18B. Applicable to anyone engaged in electronic maintenance and manufacturing Settings.

Feature:

600 V Cat III safety design index.

The display range is 50% and the backlight is bright white.

Intelligent LED test lighting LED (regardless of polarity) allows you to test LED in two modes:

DMM LED socket test mode.

LED test mode on UUT (PCBA) (using test lead)

Voltage, resistor, current, capacitance.

Diode testing, data retention.

Frequency and duty ratio.

The input terminal’s ac and dc current measurements are 10A

Technical indicators

Precision specifications

Can keep 1 year after the calibration accuracy, the work temperature of 18 ° C to 28 ° C, relative humidity of 0% to 75%. The precision form is as follows: + / + ([reading %] + [lowest effective digit]).

Function,                                          Range                     Resolution,        Precision.

Ac voltage
(40 Hz – 500Hz)1

4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

1.0 % + 3

DC voltage

4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

0.5 % + 3

Ac voltage (millivolt)

400.0 mV

0.1 mV

3.0 % + 3

Dc voltage (millivolt)

400.0 mV

0.1 mV

1.0 % + 10

Diode test

2.000 V

0.001 V

10%

Resistance

(ohm)

400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ

0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ

0.5 % + 3

o.5 % + 2

o.5 % + 2

0.5 % + 2

0.5 % + 2

1.5% + 3

Capacitance

40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF

0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF

2 % + 5

2 % + 5

5 % + 5

5.0 % + 5

5 % + 5

5 % + 5

frequency 1
Hz
(10 Hz – 100 kHz)

50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

0.1 % + 3

Duty ratio1

1 % – 99 %

0.1%

1 %Typical case4

Alternating current μA
(40 Hz – 400 Hz)

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

Alternating current mA
(40 Hz – 400 Hz)

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

Alternating current A
(40 Hz – 400 Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

Dc current μA

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

Dc current mA

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

Dc current A

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

1, the range of all current, frequency and duty ratio is 1 % to 100 % of the range. The input value is not specified below the range of 1 %.

2,Normally, the open circuit test voltage is 2.0v and short-circuit current < 0.6ma.

3,The specification does not include the error caused by the test lead capacitance and capacitance plate (the maximum error is 1.5nf when the range is 40 nF).

4, usually means that the frequency is 50 Hz or 60 Hz, which is between 10 % and 90 %.

Function

luminance range

measuring range

resolution

precision.

LED VF test 1(LED test socket)

1.00 to 6.00 V

NA

N/A

NA

LED VF test 2 (test lead)

1.00 to 6.00 V

1.00 to 6.00 V

0.01 V

10 % 3

Breaking threshold

NA

N/A

NA

70Ω

1. Open circuit test voltage is plus or minus 12 V, short circuit current > + 5 mA (usually)

2 open circuit test voltage is plus or minus 12 V, short circuit current > plus or minus 3 mA (usually)

3 VF measurement, the driving current is lower than 2.2 + 0.4ma.

 

Function,

overload protection

input impedance (nominal value)

common mode rejection ratio,

conventional mode rejection ratio.

Ac voltage

1000 V1

>10 MΩ <100 pF

In direct current,

50 Hz or 60 Hz, greater than 60 dB.

Ac voltage (millivolt)

400 mV

>1MΩ<100 pF

At 50 Hz or 60 Hz, greater than 80 dB.

Dc voltage

1000 V1

>10 MΩ <100 pF

In direct current,

50 Hz or 60 Hz, greater than 100 dB.

At 50 Hz or 60 Hz, greater than 60 dB.

Dc voltage (millivolt)

400 mV

>1MΩ<100 pF

At 50 Hz or 60 Hz, greater than 80 dB.

1, 10, 6 V Hz maximum.

General technical indicators

Maximum voltage between any terminal and ground.

1000 V

Display (LCD)

4000 counts, updated 3 times per second.

The battery type

2 AANEDA 15AIEC LR6

Battery life.

Minimum 500 hours of LED test mode and 50 hours without load. With load, battery life depends on the type of LED being tested.

temperature

Working temperature

0 °C – 40 °C

Storage temperature

-30 °C – 60 °C

Relative humidity

Working humidity

The condensation (< 10 ° C)

10 ° to 30 ° C, C less than or equal to 90% RH.

When you go from 30 to 40 C, it’s less than or equal to 75%.

40 M Ω range

10 ° to 30 ° C, C less than or equal to 80% RH.

30 ° C to 40 ° C, less than or equal to 70%

At an altitude of

Working temperature

2000 m

Storage temperature

12000 m

The temperature coefficient of

0.1x (specified precision)/C (< 18%c or >28 C)

Fuse protection for current input.

440 mA, 1000 V fast melting, limited only to the specified Fluke parts.

11A, 1000V fast melting, limited to the specified Fluke parts.

Volume (height x width x length)

183 x 91 x 49.5 mm

The weight of the

455 g

The IP rating

IP 40

security

IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, pollution level 2.

Electromagnetic environment

IEC 61326-1 portable

Electromagnetic compatibility

Only in Korea.

Class A equipment (industrial broadcasting and communications equipment) 1.

This product meets the requirements of the industry (A) electromagnetic wave equipment, the salesman or.

Users should be aware of this. The equipment is suitable for business environment.

Not suitable for family use.

Model and accessories