FLUKE 568-2
- Stock: In Stock
- Model: Digital infrared thermometer with Interface -40°C to 800°C
Specifications:
Fluke 566 and 568 is discontinued in Dec.,2015, now replacement is fluke 566-2 and 568-2.
Fluke 568-2 and 566-2 contact and non-contact thermometer the second strong, easy to use user-friendly design, you can easily cope with the rigors of industrial, electrical and mechanical environment.The performance of these tools far beyond the other infrared thermometer (pyrometer), let in more areas of application, the user can achieve higher productivity Infrared thermometer can not only close measurement, distance measurements, don't need to use a ladder .
- temperatrue range: -35 °C to 850 °C /-40 °F to 1472 °F (568-2),or -35 °C to 750 °C/-40 °F to 1202 °F (566-2)
- With soft key buttons and dot matrix display, easy access to advanced features
- D:S: 30:1
- Compatible with all standard mini-connector k-type thermocouple
- Adjustable radiation coefficient functions (built-in materials), allows users to rest assured measuring various surface
- Capture more data points (more than 20), available for download and later calls
- 2 species the backlight level height, easy to adapt to varying lighting conditions
- Audio and Visual alerts, prompts the user to measure whether the value exceeded the set limit value
- MIN,MAX,DIF feature helps you to quickly identify problems
- arracury: 1 %
- Multifunctional interface is available in 6 languages available
Specification:
Temperature range |
-35~850°c |
Resolution |
0.1°c(0.1°F) |
D:S(Distance to spot size) |
35:1 |
Emissivity selector |
0.1 ~ 1.0 adjustable by 0.01 |
Accuracy |
± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F |
Response time |
500ms (95%rdg) |
Repeatability |
±0.5 % rdg, ±1 °C |
Spectral response |
8um~14um |
Laser sights |
Single-point laser |
Laser off |
Laser at an ambient temperature over 40 ° c (104 ° f) |
Laser Power |
2(II) <1mW, 630~670nm |
Relative humidity |
10%~90%RH, <30°c |
Power |
2* AA batteries |
Battery life |
12 hours |
Hold time |
7 second |
Backlit |
yes |
Warranty |
2 years |
Operate Temperature |
0~50°c (32~120°F) |
Store Temperature |
-20~65°c (-25~150°F) |
Max. Min. Dif Temperature |
yes |
K-type thermocouple micro connector input |
yes |
K-type thermocouple Velcro pipe probe |
yes |
Heating, ventilation, air conditioning and refrigeration (HVAC) measuring Guide |
yes
|