Product overview: Fluke 715 Volt/mA Loop Calibrator

The Fluke 715 Volt mA Calibrator delivers outstanding performance, durability, and reliability in a compact, lightweight tool. Offered in the rugged Fluke 80 Series DMM package, the calibrator measures loop current as well as voltage output. It sources voltage to 200 mV or 20 V, measures loop current (0-20 mA, 4-20 mA) signals with 0 .01 % accuracy and 1 µA resolution, and measures voltage output process signals from PLCs and transmitters. It can source or simulate 4-20 mA loop current and provides a 24 V loop supply with simultaneous current measurement.

The 715 is also extremely easy to use with a simple push button interface similar to the multifunction Fluke 750 Series Documenting Process Calibrators. It features the rugged construction that Fluke tools are known for and is EMI tolerant and dust and splash resistant. It also features a removable battery door for quick battery changes.

Other useful features:

  • Provides step and linear ramp output function
  • Features configurable zero and span settings
  • Provides 24V loop supply with simultaneous current measurement
  • Features enhanced voltage and current measure and source accuracy
  • Is EMI tolerant, dust/splash resistant and features a removable battery door for quick battery changes
  • Includes a 250 ohm HART resistor with loop power
  • Comes with a protective yellow holster with test lead storage
  • Is compatible with ToolPak magnetic meter hanging system

    Key features
  • Compact, lightweight mA calibrator for measuring loop current (0-20 mA, 4-20 mA) signals
  • Delivers very high accuracy—0.01%—and 1 mA resolution
  • Measures voltage output process signals from PLCs and transmitters
  • Sources or simulates 24 mA loop current
  • Sources voltage to 100 mV or 10V
  • Provides typical 18hour battery life

Specifications: Fluke 715 Volt/mA Loop Calibrator

Functional Specifications

Measure / Source mV

Range

0 to 200 mV

Resolution

0.01 mV

Accuracy

0.015% + 2 counts

Measure / Source V

Range

0 to 20 V

Resolution

0.001 V

Accuracy

0.01% + 2 counts

Measure / Source/ Simulate mA (% of span)

Range

0 to 24 mA (-25% to 125%)

Resolution

0.001 mA

Accuracy

0.01% + 2 counts

Sink (simulate transmitter) display mA or % of span

Specifications

Loop power

Range

24 V DC

Accuracy

±10%

Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V

Display

Clear 5 digit LCD

Environmental Specifications

Operating temperature

-10°C to 55°C

Storage temperature

-40°C to 60°C

Humidity (without condensation)

95% (10°C to 30°C)

75% (30°C to 40°C)

45% (40°C to 50°C)

35% (50°C to 55°C)

Operating altitude

3,000 m max

Safety Specifications

Safety

CSA C22.2 No. 1010.1:1992

Mechanical and General Specifications

Size (L x W x D)

187 x 87 x 32 mm

(7.93 x 3.86 x 2.06 in)

Weight

Approx. 330 g