Main Menu / Categories
Your Cart

Fluke 773

Fluke 773
  • Stock: In Stock
  • Model: Milli Amp Process Clamp Meter
235,000
+ 450 Shipping charges

Details:
Milliamp process clamp meters can measure mA signals without breaking the loop. The Fluke 773 mA Clamp Meter is Fluke’s premier mA Clamp Meter, providing you with the best in troubleshooting and process calibration power.
Overview:
Here are some specific ways the Fluke 773 Clamp Meters will help you:

Milliamp Clamp Features

Application

How it saves time and money

Measure mA signals for PLC and control system analog I/O without breaking the loop.

Measures low level dc current

Correlate process indication with real physical value

Measure output signals from transmitters without breaking the loop

Maintain and troubleshoot process and automation equipment without breaking the loop

No disruption to the process

Detachable clamp with extension cable

Measurements in tight locations

Enables measurements in difficult situations

Source, simulate and measure mA signals in circuit (break the loop)

Confirm non-contact measurement. ve the next tool in hand for troubleshooting (source simulate)

Eliminates the need to return to the shop to get a loop calibrator for troubleshooting after finding a bad signal with non-contact measurement

Source and measure VDC

Troubleshoot voltage input and output devices.

Measure presence of 24V loop power. Measure 1 to 5 or 0 to 10V process signals. Test chart recorders

4 to 20 mA In/out

Dual channel mA source and measurement for troubleshooting

Source 4 to 20 mA signals into valves and mA signal conditioners and simultaneously measure 4 to 20 mA positioning output signals.

4 to 20 mA scaled output

Scaled mA output provides a mA signal output representative of the measured mA value

Connect a logging DMM and log the mA signal without breaking the loop

Loop power supply

Power a transmitter

Substitute testing of the installed 24V loop power supply. Power a transmitter and measure its mA output signal for troubleshooting.

Dual backlit display with both mA measurement and percent of 4 to 20 mA span

Clear measurement presentation

Allows quick measurement evaluation

Measurement Spotlight

Illuminates hard to see wires in dark enclosures

Measurement process is easier and quicker

Measure up to 99.9 mA range non-contact

Wide range of measurements

Measures 10 to 50 mA signals in older control systems

Automatic power off

After 15 minutes and 2 minute automatic off for backlight and spotlight

Saves battery life

 
Features:
  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ”breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing
  • DC voltage measurement to verify 24V power supplies or voltage I/O signals
  • Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
  • Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
  • Enables milliamp signal logging to a separate logging device without breaking the loop
  • Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
  • mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
  • Apply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators
  • Voltage output linear ramp or 25% step output
  • Automatically change the voltage output for remote testing

Specifications:


Environmental Specifications

Diameter of measurable conductor

0.177 or 4.5 mm max

Operating temperature

-10 to 50 ºC

Storage Temperature

-25 to 60ºC

Operating Humidity

< 90% @ <30 ºC, < 75% @ 30 to 55ºC

Operating Altitude

0 to 2000 m

IP Rating

IP 40

Size

44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)

Weight

410 g, (14.4 oz)

Vibration

Random 2 g, 5 to 500 Hz

Shock

1 meter drop test (except the jaw)

EMI/RFI

Meets EN61326-1 
Note: For current measurement w/ JAW, add 1mA to 
specification for EMC field strengths of 1V/m up to 3V/m.

Temperature Coefficient

0.01% ºC 
(<18ºC or > 28ºC)

Power, battery life

(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms

Warranty

Three years for electronics 
one year for cable and clamp assembly

 

Functional Specifications

mA measurement 
(Measured by clamp) 771/772/773 

Resolution and Range:          0 to 20.99 mA
Accuracy:                             0.2%+5 counts
Resolution and Range:          21.0 mA to 100.0 mA
Accuracy:                             1% + 5 counts

mA measurement 
(Measured in series with test jacks) 772/773 

Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts 

mA source (Maximum mA Drive: 
24 mA into 1,000 ohms) 

Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts 

mA simulate 
(Maximum voltage 50 V dc) 

Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts

Voltage source (2 mA maximum drive current)

Resolution and Range:          0 to 10.00 V dc
Accuracy: