Fluke 789
- Stock: Pre-Order
- Model: ProcessMeter
Product overview: Fluke 789 ProcessMeter™
Fluke 789 ProcessMeter doubles your troubleshooting power and is Fluke Connect-enabled
The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a loop calibrator with the power of a digital multimeter, and the wireless capabilities of Fluke Connect connectivity with optional IR3000FC module. The 789 has a display that's not only twice as large as the Fluke 787B, but also twice as bright with two levels of backlighting. And its built-in, selectable 250 ohm HART® resistor eliminates the need to carry a separate resistor.
The 789 also has a 24-Volt loop supply, which reduces the need to carry a separate power supply when doing offline transmitter testing. You can add an optional temperature measurement module and the wireless data logging capabilities of the Fluke Connect™ mobile app to log data wirelessly to your smart phone and review it from a remote location. So now process technicians can do a lot more while carrying a lot less.
Other useful features:
- Includes 0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check
- Provides all standard DMM capabilities including frequency measurement to 20 kHz, Min/Max/Average/Hold/Relative modes, and diode test and continuity beeper
- Simultaneous displays mA and % of scale readings
- Provides 20 mA DC current source/loop calibrator/simulator
- Offers manual step (100%, 25%, Coarse, Fine) plus auto step and auto ramp
- Delivers 0.1% dc voltage accuracy and 0.05% dc current accuracy
- Provides 1200 ohm drive capability on mA source
- Offers HART mode setting with loop power and a built-in 250 ohm resistor
- Offers externally accessible fuses and batteries for easy replacement
Specifications: Fluke 789 ProcessMeter™
Specifications |
||
Current
measurement |
Range |
0-1 A
AC or DC |
Resolution |
1 mA |
|
Accuracy |
0.2% +
2 LSD (DC) |
|
Range |
0-30 mA |
|
Resolution |
0.001
mA |
|
Accuracy |
0.05% +
2 lSD |
|
Current
sourcing |
Range |
0-20 mA
or 4-20 mA |
Resolution |
0.05%
of span |
|
Drive
capability |
24 V
Compliance or 1200 Ω @ 20 mA |
|
Frequency |
to
19.999 kHz, 0.005% + 1 LSD |
|
Continuity |
Beeps
for resistance < 100 Ω |
|
Voltage
measurement |
Range |
0-1000
V AC (true-rms) or DC |
Resolution |
0.1 mV
to 1.0 V |
|
Accuracy |
0.1%
Rdg + 1 LSD (VDC) |
|
Resistance
measurement |
to 40
MΩ, 0.2% + 1 LSD |
|
Diode
test |
2.0 V
shoes diode voltage drop |
|
Display
current and % of span |
Yes |
|
Auto
Step, Auto Ramp |
Yes |
|
Environmental Specifications |
||
Operating
temperature |
-20°C
to 55°C |
|
Storage
temperature |
-40°C
to 60°C |
|
Humidity
(without condensation) |
95% up
to 30°C |
|
Temperature
coefficient |
0.05 x
(specified accuracy) per °C (for temperatures < 18°C or > 28°C) |
|
Safety Specifications |
||
Electrical
safety |
Designed
in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No
1010.1-92 |
|
Overvoltage
category |
IEC
1010-1 CAT III 1000 V |
|
Maximum
voltage |
1000 V
RMS |