Product Description:

FUZRR FR2060 AC 60V~600V 3 Phase Tester Rotation Indicator Tester

Function:

Phase detection (normal phase, reverse phase),

live line inspection, simple electricity inspection,

phase loss judgment, circuit breaker search, breakpoint location,

and line maintenance Test

method: non-contact clamping method

Live electricity range:AC70~1000V Clamp wire size:

Outside diameter ø1.5mm~ø48mm Illuminated buzzer have

Application:

FR2060 non-contact phase detector is a major breakthrough in

traditional phase sequence detection methods. The traditional phase sequence

detection must be to open the three-phase wire terminal, the phase sequence

table of the three exposed clips or test pins are connected to the exposed

three fire lines. The FR2060 uses clamp-type non-contact inductive measurement.

It does not need to open the wire, and does not need to touch the high voltage

exposed live wire. It can directly detect the phase sequence by sandwiching the

three super induction high-insulation clamps to clamp the three-phase live wire

insulation sheath. At the same time, the acousto-optic indicates the normal or

reverse phase state of the phase sequence of the three-phase power supply. It

also has functions such as live line inspection, easy power inspection, open

circuit search, break point location, and line maintenance

Technical Specification:

Function Phase detection (normal phase, reverse phase), live line inspection, simple electricity inspection, phase loss judgment, circuit breaker search, breakpoint location, and line maintenance.

Power9V battery, continuous use time is about 70 hours.

Measure mode on-contact clipping method

Wire position The measured wire is in the center of the jaw

Frequency50Hz/60Hz Automatic Identification

Live electricity rangeAC70~1000V,45/65Hz(Sine wave continuous input),Conducted electrostatic detection

Measuring the highest voltageAC1000V

Clamp wire size Outside diameter ø1.5mm~ø48mm

Display[Positive phase]4 phase detector lights are turned on in a clockwise direction;

[Reverse phase]4 4 phase detection lights are turned on counterclockwise;

[Live electricity]L1, L2, L3 lights in the voltage setting range;

[Lack of phase]L1 or L2 or L3 lights are not lit;

[Open circuit]L1 or L2 or L3 lights are not lit

Beep[Positive phase]The instrument emits intermittent short beep;

[Reverse phase]The instrument emits a continuous long beep.

Battery check After the power is turned on, the power indicator is on; the battery is low; the LOW BATTERY lamp is on.

Clamp lead length0.6m

Instrument size L 117.6mm×W 81mm×T 25mm

Automatic shut-down After about 6 minutes of power on, the meter automatically shuts down to reduce battery consumption.

Battery voltage When the battery voltage drops to about 5.2V, the battery voltage is low symbol to remind to replace the battery

Instrument weightInstrument:260g(including battery)

Maximum rated power300mVA

Working temperature and humidity-10℃~55℃;below 80%rh

Storage temperature and humidity-20℃~60℃;below 90%rh

Insulation strength3.7kVrms

Suitable for Safety RegulationsEN61010-1:2001,EN61010-031:2002,pollution grade 2,CAT Ⅲ(600V),Instant overvoltage 6000V.