Main Menu / Categories
Your Cart

FR3015E FUZRR

FR3015E FUZRR
FR3015E FUZRR
Pre-Order
FR3015E FUZRR
FR3015E FUZRR
FR3015E FUZRR
  • Stock: Pre-Order
  • Model: Digital Insulation Resistance Tester

FR3015 Digital Insulation Resistance Tester

Rated voltage (V):1002500V

Insulation resistance range:0.06MΩ 100.0GΩ

Insulation resistance resolution:0.01MΩ

DC voltage range:2.01000V

AC voltage range:2.0750V

 

Model

FR3015

FR3015E

Rated voltage (V)

100-1000V

250-2500V

Insulation resistance range  

0.06MΩ-50.00GΩ

0.10MΩ-100.0GΩ

Insulation resistance resolution

0.01MΩ

0.01MΩ

DC voltage range

2.0 1000V

2.0 1000V

DC voltage resolution

0.1V

0.1V

AC voltage range

2.0 750V

2.0 750V

AC voltage resolution

0.1V

0.1V

Absorption ratio and polarization index measurement

USB data upload function

Data storage

Real-time indicator of battery power

Backlight

Battery low voltage indicator

 

Function

Insulation resistance test, voltage test

Baseline conditions

23±5, below 75%rh

Rated voltage (V)

1002500V

Measuring voltage (V)

Rated voltage × (1±10%)

Insulation resistance range

0.06MΩ 100.0GΩ

Insulation resistance resolution

0.01MΩ

DC voltage range

2.01000V

DC voltage resolution

0.1V

AC voltage range

2.0750V

AC voltage resolution

0.1V

Output short circuit current

≥ 1.5mA ( 10 00V)

Absorption ratio and polarization index measurements

Have

Power supply

1.5V ( AA ) alkaline batteries 8 pieces

Backlight

Controllable gray and white screen backlight, suitable for use in dark places

Auto off

Instrument shut down after 15 minutes without operation

Display mode

4-digit super large LCD display, gray and white screen backlight

LCD display size

73 mm x 43 mm

Meter size

175mm (L)× 112mm (W)× 53mm (H)

Test line

High voltage test line red 1 meter, black 1 meter

USB interface

· 

With USB interface, data reading, save record data

Data storage

500 groups, flashing “FULL” symbol means storage is full

Data review

Data query function: “MEM”symbol display

Overflow display

Over-range overflow function:”OL”symbol display

Power consumption

Standby time: 18mA Max (backlight off)

 

Power on backlight: 43mA Max

 

Measurement: 326mA Max (with backlight on )

Quality

1230g (including battery)

Battery voltage

The battery voltage is insufficient, and the low battery symbol ”    ” is displayed

Insulation resistance

≥50MΩ (1000V)

withstand voltage

AC3kV/50Hz 1min

Operating Temperature and Humidity

-10+5085%RH

Storage Temperature and Humidity

-15+5590%RH

Suitable for safety regulations

IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529 (IP54), pollution, etc. 2, CAT 300V