FR3015E FUZRR
- Stock: Pre-Order
- Model: Digital Insulation Resistance Tester
FR3015 Digital Insulation Resistance Tester
Rated voltage (V):100~2500V
Insulation resistance range:0.06MΩ ~ 100.0GΩ
Insulation resistance resolution:0.01MΩ
DC voltage range:2.0~1000V
AC voltage range:2.0~750V
Model |
FR3015 |
FR3015E |
Rated voltage (V) |
100-1000V |
250-2500V |
Insulation resistance range |
0.06MΩ-50.00GΩ |
0.10MΩ-100.0GΩ |
Insulation resistance resolution |
0.01MΩ |
0.01MΩ |
DC voltage range |
2.0 ~ 1000V |
2.0 ~ 1000V |
DC voltage resolution |
0.1V |
0.1V |
AC voltage range |
2.0 ~ 750V |
2.0 ~ 750V |
AC voltage resolution |
0.1V |
0.1V |
Absorption ratio and polarization index measurement |
● |
● |
USB data upload function |
● |
● |
Data storage |
● |
● |
Real-time indicator of battery power |
● |
● |
Backlight |
● |
● |
Battery low voltage indicator |
● |
● |
Function |
Insulation resistance test, voltage test |
Baseline conditions |
23℃±5℃, below 75%rh |
Rated voltage (V) |
100~2500V |
Measuring voltage (V) |
Rated voltage × (1±10%) |
Insulation resistance range |
0.06MΩ ~ 100.0GΩ |
Insulation resistance resolution |
0.01MΩ |
DC voltage range |
2.0~1000V |
DC voltage resolution |
0.1V |
AC voltage range |
2.0~750V |
AC voltage resolution |
0.1V |
Output short circuit current |
≥ 1.5mA ( 10 00V) |
Absorption ratio and polarization index measurements |
Have |
Power supply |
1.5V ( AA ) alkaline batteries 8 pieces |
Backlight |
Controllable gray and white screen backlight, suitable for
use in dark places |
Auto off |
Instrument shut down after 15 minutes without operation |
Display mode |
4-digit super large LCD display, gray and white screen
backlight |
LCD display size |
73 mm x 43 mm |
Meter size |
175mm (L)× 112mm (W)× 53mm (H) |
Test line |
High voltage test line red 1 meter, black 1 meter |
USB interface |
· With USB interface, data reading, save record data |
Data storage |
500 groups, flashing “FULL” symbol means storage is full |
Data review |
Data query function: “MEM”symbol display |
Overflow display |
Over-range overflow function:”OL”symbol display |
Power consumption |
Standby time: 18mA Max (backlight off) |
|
Power on backlight: 43mA Max |
|
Measurement: 326mA Max (with backlight on ) |
Quality |
1230g (including battery) |
Battery voltage |
The battery voltage is insufficient, and the low battery
symbol ” ” is displayed |
Insulation resistance |
≥50MΩ (1000V) |
withstand voltage |
AC3kV/50Hz 1min |
Operating Temperature and Humidity |
-10℃~+50℃<85%RH |
Storage Temperature and Humidity |
-15℃~+55℃<90%RH |
Suitable for safety regulations |
IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529 (IP54),
pollution, etc. 2, CAT Ⅲ 300V |