UNI-T UTD2102e Digital Oscilloscope with large 7" display and 100MHz bandwidth, 32K record length for 2 channel with highest 500Ms/s sample rate. It is a widely used electronic measuring instrument, can transform the electrical signals into visible images, so that people can study the changes of various electrical phenomena.
Features:
Wide and Sensitive Scopemeter --- 100MHz bandwidths; 500Ms/S Real Time sample rate; Dual analog channels wide vertical range 1mV/div~20V/div.
Fast Convenience Capture Digital --- With copy function for fast storage infomation; Record length up to 32K, and waveform record up to 1000 screen.
Reliable Electronic Measuring Tool --- High accuracy and wide measurement range meet different analyze demands.
Easy to Use --- Supports plug-and-play USB storage device. Communication with and remote control of computer through the USB device. Multilingual menu available, with multiple functional button for fast operation.
Large Display More Easy Reading --- 7 inch large TFT LCD display with 800×480 pixels RGB, large and vivid more, make monitor and analyze work more easy.
Wide Application --- electronic circuit debugging / circuit testing / design and manufacture / education and training / automobile maintenance and testing.
Specifications:
Model | UTD2012e | |
Channel | 2 | |
Bandwidth | 100MHz | |
Acquisition modes | ||
Real Time sample rate | 500MS/s | |
Equivalent sampling | 50GS/s | |
Average | 2 channels simultaneously, can counter the average of 2 n times.and n=1~8 positive integers can be selected. | |
Input | ||
Input Coupling | DC, AC, and GND | |
Input Impedance | 1ΜΩ±2%, in parallel with 20pF±3pF | |
Probe Attenuation Factor | 1×,10×,100×,1000× | |
Max. Input Voltage | 400V(DC+ACpeak,1ΜΩinput resistance)(10:1 probe attenuation) | |
Channel Isolation | Over 40:1 | |
Channel Time Delay(typical) | 150ps | |
Horizontal | ||
Interpolation | sin (x) / x | |
Memory Depth | 32K | |
Horizontal Scale (s/div) | 2ns/div ~ 50s/div, step by 1-2-5 | |
Sampling Rate / Relay Time Accuracy | ±50ppm(any≥1ms time interval) | |
Horizontal Display | 12div | |
Interval (△T) | Single:± (1 interval time + 50ppm × reading + 0.6ns) | |
Accuracy (full bandwidth) | average≥16 : ±(1 interval time + 50ppm × reading + 0.4ns) | |
Vertical | ||
Vertical Resolution(A/D) | 8 bits (2 channels simultaneously) | |
Horizontal Sensitively Range(V/div) | 1mV/div -20V/div(in BNC) | |
Displacement Range | ±10div | |
Vertical Bandwith | 100MHz | |
Low frequency response (AC coupling, -3dB) | ≤5Hz( over BNC) | |
Rais Time (BNC typical) | ≤3.5ns | |
DC Gain Accuracy | As Vertical sensitivity is 1mV~5mV/div:±4% (acquisition or average value acquisition modes); | |
As Vertical sensitivity is 10mV/div~20V/div:±3% (acquisition or average value acquisition modes); | ||
DC Measurement Accuracy(average value acquisition modes) | Vertical displacement = 0 , and N≥16: ±(5%×reading + 0.1div + 1mV)and select 1mV/div or 2mV/div; ±(4%×reading + 0.1div + 1mV)and select 5mV/div; ±(3%×reading + 0.1div +1mV)and select 10mV/div~20V/div. | |
Vertical displacement ≠ 0, and N≥16: ±[3%×( reading + Vertical displacement reading)+(1%×Vertical displacement reading )]+0.2div) | ||
set from 5mV/div to 200mV/div + 2mV; setting value from 200mV/div to 20V/div + 50mV. | ||
Voltage difference (ΔV) measurement accuracy (average acquisition method) | Under the same setting and condition, take the averege value for ≥16 capture waveform, | |
voltage difference between any two point of the waveform(ΔV):±(3% × Reading + 0.05div ) | ||
Trigger | ||
Trigger Sensitive | 1div | |
Trigger level range | Internal | ±5 divisions from screen center |
EXT | ±3V | |
Trigger level average(typical)accuracy aims to the signal up and dowm times≥20ns | Internal | ±(0.3div×V/div)(±4 divisions from screen center) |
EXT | ±(6% set value +40mV) | |
Trigger ability | Nomal/Scan Mode,Pre/Delay Trigger,pre-trigger depth adjustable | |
Release range | 100ns~1.5s | |
Set the level to 50% (typical) | Operate when Input singnal frequency≥50Hz | |
Edge Type | Rise, fall, rise and fall | |
Trigger Mode | (>, < , =) +Bandwith,(>, < , =) -Bandwith | |
Trigger Level | 20ns-10s | |
CH1 Trigger | Edge, bandwidth | |
CH2 Trigger | Edge, bandwidth | |
Measurement | ||
Cursor | Manual | △V, and △T between cursors, 1/ΔT(Hz) |
Track | Voltage value and time value of the waveform point | |
Auto | Allow cursor appear when auto measure | |
Auto Measure | Vpp, Amplitude, Vmax, Vmin, Vtop, Vbase, Vmed, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay A→B , Delay A→B , | |
Waveform Math | +, -, ×, ÷, invert | |
Storage | 20 waveform,20 kinds of setting,BMP | |
FFT | Window | Hanning,Hamming,Biackman-Harris,Rectangular |
Sample point | 1024 points | |
Lissajous Figure | Bandwidth | 100MHz |
Phase Difference | ±3 degrees | |
Output Voltage(Typical) | about 3V,Peak-to-peak≥1MΩ load | |
Frequency (Typical) | 1kHz | |
Display | ||
Display | 7inch TFT , 800×480 pixels RGB | |
Waveform and grid | adjustable light for waveform and grid | |
Language | Chinese Simplified, Chinese Traditional, English, Portuguese, Spanish, French, Dutch, German, Russian | |
Other | ||
Waveform Record | 1000 screen,Can be temporarily stored or stored to a USB flash drive | |
Frequencycouter | 6-bit hardware frequencycouter | |
Screen Copy | one key copy screen function | |
Frequency (Typical) | 1kHz | |
Standard Configuration | USB-OTG:for digital storage and communicate with a PC | |
Plug Type | EU / UK / US (Optional) | |
Power Supply | 220V (EU/UK plug), 110V (US plug), 50/60Hz | |
Power Consumption | < 50W | |
Fuse | 2A, T class, 250V | |
Temperature | Working Temperature :10℃~+40℃; Storage Temperature:-20℃~+60℃ | |
Humidify | <35℃:90%RH,+35℃~+40℃:≤60%RH | |
Altitude | Working altitude 2,000M; storage altitude15,000M | |
Item Size | 350 * 145 * 115mm / 13.8 * 5.7 * 4.5in | |
Net Weight | 1793g / 63.2oz | |
Pacakge Weight | 2644g / 93.3oz |