Main Menu / Categories
Your Cart

W3230 AC110-220V

W3230 AC110-220V
  • Stock: In Stock
  • Model: Digital Temperature Controller Microcomputer
1,200
+ 300 Shipping charges

W3230 AC 220v DC 12V Digital Thermostat Temperature Controller Product description:

  • Mini temperature controller.
  • With a clear LED display for better readability.
  • Wide temperature measuring range.
  • Heating or cooling control.
  • All parameters set can be saved after a short circuit.
  • Relay output.
  • High Control precision 0.1 centigrade
  • Can be used for domestic freezer, water tanks, refrigerator, industrial chiller, steamer, industrial equipment and other
  • temperature-controlled system.

Specification:

  • Power Supply: 110V – 220V AC; Color of Displaying: red/blue; Sensor: NTC10K Waterproof sensor
  • Output: Relay Contact Capacity 10A 220V / 20A 12V / 20A 24V
  • Temperature Control Range:-55°-120°; Resolution Ratio: 0.1°C(-9.9-99.9); 1°C(other range)
  • Measurement accuracy: ±0.1°C; Control accuracy: 0.1°C
  • Environmental requirements: -10-60°C , humidity 20%-85%RH; Dimension:79mm*43mm*26mm; Cutting Size:73mm*39mm; Sensor wire: 1 meter
  • Temperature Setting
    After the temperature controller is connected to the power, the actual temperature is shown on the red
    display. When you press the SET key, the blue display will flash. Press UP and DOWN keys to adjust the
    temperature.
    P0: Working Mode
    This value should be set when you start using the thermostat. If it is used for heating, this parameter
    should be set to “H”. Otherwise, if used for cooling it should be set to “C”.
    P1: Hysteresis
    The difference between the temperature at which the thermostat switches off – and the temperature at
    which it switches on again.
    Example: We set the heating mode and the temperature is 37~40°C – The hysteresis is 3°C.
    P2-P3: Setting Limits
    These functions set the limit values of the temperature range. Under the normal state, the setting range is
    between -40°C and +120°C. If you don’t need so big range, you can set the values of these parameters to
    shorten it.
    Example: P2 is set to 50°C, P3 is set to 20°C – The temperature can be set from 20°C to 50°C.
    P4: Temperature Correction
    This function is used to correct the temperature in case there’s a deviation between the measured
    temperature and the actual temperature.
    Example: We measure the temperature of 25.6°C and the actual temperature is 25.8°C – You can set P4
    to 0.2°C, so the displaying temperature will be 25.8°C.
    P5: Delay Start
    This function is generally used for cooling the refrigeration compressor. So, if you purchase the
    thermostat for the refrigerator, this value has to be set to 3-6 minutes (depending on the size of the
    compressor). If it doesn’t control the compressor, this value should be set to 0.
    P6: High-temperature Alarm
    When the actual temperature exceeds the upper temperature limit of +120°C, the thermostat will display
    flashing “CCC” on the red display. In case of a short circuit, the blinking “LLL” message will be shown
    on the red display.
    P7: Data Lock
    If you need to prevent other people from changing your set temperature, you can set P7 to ON after
    finishing the setting of the parameters. After setting to ON, the temperature and the internal parameters
    cannot be changed.
    P8: Restore Factory Settings
    By setting P8 to ON, all the settings will be reverted to their factory default.
    P9: Temperature Scale
    You can switch between Celsius (°C) and Fahrenheit (°F) temperature scale by modifying value of this
    parameter (“HS” – Celsius, “FC” – Fahrenheit).
    Setting Examples
    Cooling Mode
    Controlling refrigeration equipment will stop cooling when the temperature is 25°C and start cooling
    when the temperature is 30°C. To set the working mode like this, follow the next steps:
    1. In the state of displaying the normal temperature, press the SET key to get the flashing numbers
    on the blue display; find the value 25.0°C by navigating with UP and DOWN buttons and finally
    press the RESTART key to confirm and get back to display state.
    2. To access the parameter setting mode, press the SET key and hold it for 5 seconds until “P0”
    appears on the screen. Then press the SET key to access the P0 code parameter. By pressing UP /
    DOWN, you can adjust between different modes. Choose “C” mode and press the RESTART key
    to confirm and get back to display state.
    3. Go to parameter setting mode again by holding the SET key for 5 seconds. When P0 is displayed
    on the screen, press the UP button to adjust to the code P1 (hysteresis) and then press SET to
    access the P1 code parameter. Adjust the value to 5.0 by navigating with UP/DOWN buttons and
    finally press the RESTART key to confirm and get back to display state.
    If you need to set other parameters, please refer to above settings.
    Heating mode
    Controlling heating equipment will stop heating when the temperature is 30°C and start heating when the
    temperature is 25°C. To set the working mode like this, follow the next steps:
    1. In the state of displaying the normal temperature, press the SET key to get the flashing numbers
    on the blue display; find the value 25.0°C by navigating with UP and DOWN buttons and finally
    press the RESTART key to confirm and get back to display state.
    2. To access the parameter setting mode, press the SET key and hold it for 5 seconds until “P0”
    appears on the screen. Then press the SET key to access the P0 code parameter. By pressing UP /
    DOWN, you can adjust between different modes. Choose “H” mode and press the RESTART key
    to confirm and get back to display state.
    3. Go to parameter setting mode again by holding the SET key for 5 seconds. When P0 is displayed
    on the screen, press the UP button to adjust to the code P1 (hysteresis) and then press SET to
    access the P1 code parameter. Adjust the value to 5.0 by navigating with UP/DOWN buttons and
    finally press the RESTART key to confirm and get back to display state.
    If you need to set other parameters, please refer to above settingsA