FLUKE 117C
- Stock: In Stock
- Model: Multimeter with Non-Contact voltage
DESCRIPTION:
Key Features:
The 117 digital multimeter is a for electricians working in
commercial and non-commercial premises that need non-contact voltage detection
for faster and safer operations.
Non-contact voltage detection
AutoVolt automatic AC/DC voltage selection
Prevent false readings caused by ghost voltage
Key Features
The 117 digital multimeter is a for electricians working in
commercial and non-commercial premises that need non-contact voltage detection
for faster and safer operations.
Non-contact voltage detection
AutoVolt automatic AC/DC voltage selection
Prevent false readings caused by ghost voltage
Specifications: Fluke 117 Electricians Multimeter with
Non-Contact voltage
Specifications |
||
Maximum voltage between any terminal and earth ground |
600 V |
|
Safety |
IEC 61010-1: Pollution Degree 2 |
|
Fuse for A input |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|
Display |
Digital: 6,000 counts, updates 4 per second |
|
Bar graph |
33 segments, updates 32 per second |
|
Operating temperature |
-10°C to +50°C |
|
Storage temperature |
-40°C to +60°C |
|
Battery type |
9 volt Alkaline, IEC 6LR61 |
|
Battery life |
400 hours typical, without backlight |
|
Accuracy Specifications |
||
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
DC volts |
Range/resolution |
6.000 V / 0.001 V |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
Auto volts |
Range/resolution |
600.0 V / 0.1 V |
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) |
|
AC millivolts¹ True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
AC volts¹ True RMS |
Range/resolution |
6.000 V / 0.001 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or
shorts of |
|
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω |
Accuracy |
0.9% + 1 |
|
Range/resolution |
40.00 MΩ / 0.01 MΩ |
|
Accuracy |
5% + 2 |
|
Diode test |
Range/resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
|
Capacitance |
Range/resolution |
1000 nF / 1 nF |
Accuracy |
1.9% + 2 |
|
Range/resolution |
> 1000 μF |
|
Accuracy |
5% + 20% |
|
Lo-Z capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
|
AC amps True RMS (45 Hz to 500 Hz) |
Range/resolution |
6.000 A / 0.001 A |
Accuracy |
1.5% + 3 |
|
DC amps |
Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy |
1.0% + 3 |
|
Hz (V or A input)² |
Range/resolution |
99.99 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
|
1. All AC voltage ranges except Auto-V/LoZ are specified
from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. |
Specifications |
||
Maximum voltage between any terminal and earth ground |
600 V |
|
Safety |
IEC 61010-1: Pollution Degree 2 |
|
Fuse for A input |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|
Display |
Digital: 6,000 counts, updates 4 per second |
|
Bar graph |
33 segments, updates 32 per second |
|
Operating temperature |
-10°C to +50°C |
|
Storage temperature |
-40°C to +60°C |
|
Battery type |
9 volt Alkaline, IEC 6LR61 |
|
Battery life |
400 hours typical, without backlight |
|
Accuracy Specifications |
||
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
DC volts |
Range/resolution |
6.000 V / 0.001 V |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
Auto volts |
Range/resolution |
600.0 V / 0.1 V |
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) |
|
AC millivolts¹ True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
AC volts¹ True RMS |
Range/resolution |
6.000 V / 0.001 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or
shorts of |
|
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω |
Accuracy |
0.9% + 1 |
|
Range/resolution |
40.00 MΩ / 0.01 MΩ |
|
Accuracy |
5% + 2 |
|
Diode test |
Range/resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
|
Capacitance |
Range/resolution |
1000 nF / 1 nF |
Accuracy |
1.9% + 2 |
|
Range/resolution |
> 1000 μF |
|
Accuracy |
5% + 20% |
|
Lo-Z capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
|
AC amps True RMS (45 Hz to 500 Hz) |
Range/resolution |
6.000 A / 0.001 A |
Accuracy |
1.5% + 3 |
|
DC amps |
Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy |
1.0% + 3 |
|
Hz (V or A input)² |
Range/resolution |
99.99 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
|
1. All AC voltage ranges except Auto-V/LoZ are specified