FLUKE 117C

FLUKE 117C
New
Tags: FLUKE 117C
FLUKE 117C
  • Stock: In Stock
  • Model: Multimeter with Non-Contact voltage
62,000
+ 500 Shipping charges

DESCRIPTION:
Key Features:

The 117 digital multimeter is a for electricians working in commercial and non-commercial premises that need non-contact voltage detection for faster and safer operations.

Non-contact voltage detection

AutoVolt automatic AC/DC voltage selection

Prevent false readings caused by ghost voltage

Key Features

The 117 digital multimeter is a for electricians working in commercial and non-commercial premises that need non-contact voltage detection for faster and safer operations.

Non-contact voltage detection

AutoVolt automatic AC/DC voltage selection

Prevent false readings caused by ghost voltage

Specifications: Fluke 117 Electricians Multimeter with Non-Contact voltage

Specifications

Maximum voltage between any terminal and earth ground

600 V

Safety

IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V

Fuse for A input

11 A, 1000 V FAST Fuse (Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to +50°C

Storage temperature

-40°C to +60°C

Battery type

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution

600.0 V / 0.1 V

Accuracy

2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)

AC millivolts¹ True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts¹ True RMS

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

AC amps True RMS (45 Hz to 500 Hz)

Range/resolution

6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy

1.5% + 3
20 A continuous overload for 30 seconds max

DC amps

Range/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy

1.0% + 3
20 A continuous overload for 30 seconds max

Hz (V or A input)²

Range/resolution

99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz

Accuracy

0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

 

Specifications

Maximum voltage between any terminal and earth ground

600 V

Safety

IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V

Fuse for A input

11 A, 1000 V FAST Fuse (Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to +50°C

Storage temperature

-40°C to +60°C

Battery type

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution

600.0 V / 0.1 V

Accuracy

2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)

AC millivolts¹ True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts¹ True RMS

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

AC amps True RMS (45 Hz to 500 Hz)

Range/resolution

6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy

1.5% + 3
20 A continuous overload for 30 seconds max

DC amps

Range/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy

1.0% + 3
20 A continuous overload for 30 seconds max

Hz (V or A input)²

Range/resolution

99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz

Accuracy

0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.