DESCRIPTION:
ES3035+ Series Digital Insulation Resistance Tester
Rated voltage(V) :100;250;500;1000;2500V;5000V
Insulation Resistance Range(GΩ):0.01MΩ~2000GΩ
DC Voltage Range :0~1000V
AC Voltage Range :0~750V
Output short-circuit Current : ≥5mA(5KV)
Function |
Insulation resistance test, voltage test |
Base conditions |
23°C±5°C,below 75%rh |
Rated voltage(V) |
250;500;1000;2500V;5000V ; 10000 |
Test Voltage(V) |
rated voltage×(1±10%) |
Insulation Resistance Range(GΩ) |
0.01MΩ~2000GΩ |
Insulation Resistance Resolution |
0.01MΩ |
DC Voltage Range |
0~1000V |
DC Voltage Range Resolution |
0.1V |
AC Voltage Range |
0~750V |
AC Voltage Range |
0.1V |
Output short-circuit Current |
≥5mA(5KV) |
Absorption Ratio and Polarization Index Measurement |
Have |
Power Supply |
12.6V rechargeable battery |
Backlight |
Controllable gray screen backlight, suitable for use in
dim places |
Dispaly mode |
4-bit large LCD display, gray screen backlight |
LCD display size |
108mm×65mm |
Instrument size |
L/W/H:277.2mm×227.5mm×153mm |
USB interface |
With USB interface, software monitoring, storage data can
be uploaded to the computer, save and print |
Communication Line |
USB communication line 1PC |
Test Line |
High voltage rob red 3meter, high voltage test line black
1.5meter, green 1.5meter |
Data Storage |
500 groups, “FULL” symbol indicates that storage is full |
Data Review |
Data review function: “MR” symbol display |
Overflow Display |
Exceed measurement range overflow function: “OL ” symbol
display |
Alarm Function |
Alarm when the measured value smaller than the alarm
setting value |
Power Consumption |
Standby: 30mA Max(backlight off) |
|
Turn on backlight: 42mA Max |
|
Measure:300mA Max(backlight off) |
Instrument weight |
2720g(including battery) |
Battery voltage |
When the battery voltage is low, low battery symbol “
”will display |
Automatic shut-down |
automatic shutdown after 15 minutes boot |
Insulation Resistance |
≥50MΩ(between Measuring line and housing) |
voltage withstand |
AC3kV/50Hz 1min |
Working Temperature and Humidity |
-10℃~+50℃<85%RH |
Storage Temperature and Humidity |
-15℃~+55℃<90%RH |
Suitable for Safety Regulations |
IEC61010-1、IEC1010-2-31、IEC61557-1,5、IEC60529(IP54)
pollution grade 2、CAT Ⅲ 300V |