ES7060 FUZRR






- Stock: Pre-Order
- Model: Intelligent live cable identification instrument
·
Frequency 6 Adjustable:640Hz、1.28KHz、2.56KHz、3.84KHz,6.50KHz,8.05KHz
·
Output voltage :The maximum peak value is about:110V
·
Transmitter clamp: inner diameter:φ125mm
wire length:3meter
·
Transmitter clamp magnetically saturated:40A(50Hz)
·
External voltage detection:Yes, up to 150V
RECEIVER TECHNICAL SPECIFICATION
Function | Live cable identification, power outage cable
identification, single-core cable identification, with FHD algorithm | |
Power supply | 8.4V/2500mAhCharable lithium battery, USB charging
interface, full power continuous operation for about 6 hours | |
Receive frequency | 6 options:640Hz、1.28KHz、2.56KHz、3.84KHz,6.50KHz,8.05KHz | |
Gain | 4 levels | |
Unique identification | Yes, the target cable display(√) | |
Filter mode | Hardware filtering + DSP digital filtering | |
FHD algorithm | Support, instrument direct results, greatly reduce the use
requirements of field personnel | |
Calibration quantity | Number of calibrated cables: 1~20 | |
Identification condition | Current, the percentage of the received and transmitted
signal between 70% and 130% of the calibration value is one of the conditions
for successful identification | |
| Signal coding, receiver decoding by the algorithm, and the
transmitter output coding is one of the successful identification conditions | |
| Signal phase, the receiver extracts the phase through the
algorithm, <50 is one of the successful conditions | |
| Current direction, the receiver judges the current signal
direction, and the calibration value comparison is one of the successful
identification pieces | |
Display mode | The 3.5-inch real color LCD screen display, color icon
indication | |
Receiver size | 172mm ×106mm ×42mm | |
Flexible current clamp | Internal diameter :φ200mm Signal line length:
3 m | |
Scope of detection | Power failure identification: the coil can detect the
composite pulse width frequency signal with circuit resistance of 0 Ω ~ 30
kΩ; generally, the cable length can be over 20 km, mainly determined by the
cable grounding resistance and cable resistance. | |
| Live identification: the coil can detect the pulse signal
with circuit resistance 0 Ω ~500 Ω; when the test circuit resistance is 500
Ω, the cable length can reach 0-10 km | |
capacity of resisting disturbance | Highest 100A(50Hz,10dB level) | |
Signal sampling rate | Adaptation for different frequency sampling rates,Max
819.2KHz | |
Armored damaged mode | Yes | |
The results show the period | About 2times/second | |
Auto shut off | After 30 minutes of no operation and no input, the
instrument will be shut down automatically to save power | |
| When the battery level is too low, the instrument will be
shut down | |
Firmware update | Support, is updated via USB | |
USB | USB Charging port | |
Working temperature and humidity | -10℃~40℃;less than 80%Rh | |
Store temperature and humidity | -10℃~50℃,≤95%RH,
no condensation | |
Receiver quality | Flexible current clamp 112g; Receiver 405g (with battery) | |
Withstand voltage | AC2000V/rms(Before the front and rear ends of the
enclosure) | |
Function | Output composite pulse width frequency signal, signal
coupling output, signal directly connected output, display output voltage,
output current, circuit impedance, residual battery voltage, and dynamic
indication of transmission state | |
Power supply | Live identification model: 9.6V / 6Ah lithium battery,
full power continuous operation for about 8 hours (3 levels output) | |
Output method | Live identification model: automatic identification,
caliper coupling during live identification; direct connection output during
power identification Power outage identification type: only power outage
identification direct connection output | |
Frequency | 6 Adjustable:640Hz、1.28KHz、2.56KHz、3.84KHz,6.50KHz,8.05KHz | |
Output interface | Waterproof aviation socket | |
Output power | Maximum 15W, 5 Levels adjustable, automatic real-time
impedance matching | |
Output voltage | The maximum peak value is about:110V | |
Armored damaged mode | Yes | |
Transmitter clamp | inner diameter:φ125mm wire
length:3meter | |
Directed connection clamp | Caliber:Max 24mm wire length:1meter | |
Transmitter clamp magnetically saturated | 40A(50Hz) | |
Human-computer interaction | Physical buttons, touch screen , gesture recognition | |
Auto shut off | Yes, no operation, no output for 30 minutes of automatic
shutdown, the time can be set | |
Automatic standby | Yes, the default no operation for 5 minutes to
automatically reduce the screen brightness to save power, the time can be set | |
External voltage detection | Yes, up to 150V | |
Charging port | Circular charging interface, DC mark | |
Fixed parts update | Support, is updated via USB | |
Transmitter size | 275mm×226mm×150mm | |
LCD size | Length width 120mm×70mm; Display field 110mm×62mm | |
Working temperature | -10℃~40℃ | |
storage condition | -20℃~50℃,≤95%RH,
no condensation | |
Working temperature | -10℃~40℃ | |
Storage condition | -20℃~50℃,≤95%RH,
no condensation | |
Instrument quality | Transmitter about 2.28kg; Transmitter clamp about 1.12kg;
The direct connection test clip is about 170g, and the total mass is about
4.44kg | |
Withstand voltage | AC 3700V/rms(Before the top surface and bottom surface of
the instrument box) | |
Electromagnetic characteristics | IEC61326(EMC) | |
Refer to safety regulations | IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、class of pollution 2) | |