FR2010E+ FUZRR

FR2010E+ FUZRR
FR2010E+ FUZRR
Pre-Order
FR2010E+ FUZRR
FR2010E+ FUZRR
FR2010E+ FUZRR
  • Stock: Pre-Order
  • Model: Double Clamp Digital Phase Voltammeter

Function

Measure two AC voltages, currents, phase between voltages, phase between currents, phases between voltages and currents, frequencies, active power, reactive power, apparent power, power factor, determine transformer wiring groups, inductive, capacitive circuits, test secondary loops and bus differential protection system, read out the phase relationship between the CTs of the differential protection groups, check the wiring of the power meter, check the line equipment, etc.

Power

DC3.7V large capacity lithium rechargeable battery

Power consumption

Turn on the backlight and consume up to 280mA. The battery can work continuously for more than 5 hours.

Display mode

LCD display71*52mm

Instrument size

L/W/T187*191*51mm

Voltage range

AC 0.00V600V

Current range

AC 0.0mA20.0A

Phase range

0.0°360.0°

Frequency range

45.00Hz65.00Hz

Active power range

-12kW12kW

Reactive power range

-12kVAR12kVAR

Apparent power range

0.012kVA

Power factor range

-1+1

Resolution

VoltageAC 0.01V

 

CurrentAC 0.1mA

 

Phase0.1°

 

Frequency0.01Hz

 

Active power:0.1W

 

Reactive power:0.1VAR

 

Apparent power:0.1VA

 

Power factor:0.001

Detection rate

About 2 seconds/time

Data hold

Press HOLD key to hold data during test, “HOLD” symbol display

Data storage

500 groups

USB interface

USB interface, uploading data to a computer for analysis of management data

Automatic shut-down

About 15 minutes after power on, the meter will automatically shut down to reduce battery consumption

Backlight function

Suitable for dim places and night use

Voltage detection

When the battery voltage is lower than 3V, the low battery voltage will display, remind to charge in time

Instrument weight

Hose450g(including battery)

 

Tip-shaped current clamp170g×2

 

Test line250g

Test line length

1.5m

Line length of the current clamp

2m

Working temperature and humidity

-1040below 80%Rh

Storage temperature and humidity

-1060below 70%Rh

input impedance

Test voltage input impedance is2MΩ

Pressure resistance

The withstand voltage of 1000V/50Hz sine wave AC voltage between the instrument circuit and the housing lasts 1 minute

insulation

Between instrument line and housing≥100MΩ

structure

Double insulation

Suitable for safety regulations

IEC61010-1 CAT  600VIEC61010-031IEC61326Pollution level 2